![YASKAWA Varispeed V7 Скачать руководство пользователя страница 248](http://html1.mh-extra.com/html/yaskawa/varispeed-v7/varispeed-v7_instruction-manual_3554366248.webp)
10. Specifications
247
104
0168
Torque Compensation
Time Constant
0.0 to
25.5 s
0.1 s
0.3 s
(Note 8)
131
105
0169
Torque Compensation
Iron Loss
0.0 to 6550
0.01 W (less
than 1000 W)/
1 W (1000 W
or more)
(Note 3)
131
106
016A
Motor Rated Slip
0.0 to
20.0 Hz
0.1 Hz
(Note 3)
132
107
016B
Line to Neutral (per
Phase)
0.000 to
65.50
Ω
0.001
Ω
(less
than 10
Ω
)/
0.01
Ω
(10
Ω
or more)
(Note 3)
132
108
016C
Motor Leakage Induc-
tance
0.00 to
655.0 mH
0.01 mH (less
than 100 mH)/
0.1 mH
(100 mH or
more)
(Note 3)
134
109
016D
Torque Compensation
Voltage Limiter
0% to
250%
1%
150%
---
110
016E
Motor No-load Current
0% to 99%
1%
(Note 3)
132
111
016F
Slip Compensation Gain
0.0 to 2.5
0.1
0.0 (Note 8)
171
112
0170
Slip Compensation Time
Constant
0.0 to
25.5 s
0.1 s
2.0 s
(Note 8)
171
113
0171
Slip Correction During
Regenerative Operation
0, 1
1
0
133
115
0173
Stall Prevention Auto-
matic Decrease Selec-
tion
0, 1
1
0
169
116
0174
Acceleration/decelera-
tion Time during Stall
Prevention
0, 1
1
0
170
117
0175
Undertorque Detection
Function Selection
0 to 4
1
0
---
118
0176
Undertorque Detection
Level
0% to
200%
1%
10%
---
119
0177
Undertorque Detection
Time
0.1 to
10.0 s
0.1 s
0.1 s
---
No.
Register
No. for
Trans-
mission
Name
Setting
Range
Setting Unit
Factory
Setting
User
Setting
Ref.
Page