![YASKAWA Varispeed V7 Скачать руководство пользователя страница 243](http://html1.mh-extra.com/html/yaskawa/varispeed-v7/varispeed-v7_instruction-manual_3554366243.webp)
242
Constants List
• Constants That Can Be Changed during Operation
The constants whose numbers are shaded can be changed during
operation.
First Functions (Constants n001 to n044)
No.
Register
No. for
Trans-
mission
Name
Setting
Range
Setting Unit
Factory
Setting
User
Setting
Ref.
Page
001
0101H
Constant Selection/Ini-
tialization
0 to 4, 6,
8, 9
1
1
127
002
0102
Control Mode Selection
(Note 6)
0, 1
1
0
(Note 1)
(Note 6)
132
003
0103
RUN Command Selec-
tion
0 to 3
1
3
137
004
0104
Frequency Reference
Selection
0 to 9
1
9
138
005
0105
Stopping Method Selec-
tion
0, 1
1
0
155
006
0106
Reverse Run Prohibit
0, 1
1
0
139
007
0107
Stop Key Selection
0, 1
1
0
154
008
0108
Frequency Reference
Selection in Local Mode
0, 1
1
1
(Note 5)
137
009
0109
Frequency Reference
Setting Method From
Digital Operator
0, 1
1
0
138
010
010A
Detecting Fault Contact
Of Digital Operator
0, 1
1
0
137
011
010B
Max. Output Frequency
50.0 to
400.0 Hz
0.1 Hz
50.0 Hz
129
012
010C
Max. Voltage
0.1 to
255.0 V
(0.2 to
510.0)
0.1 V
200.0 V
(Note 2)
129
013
010D
Max. Voltage Output
Frequency (Base Fre-
quency)
0.2 to
400.0 Hz
0.1 Hz
50.0 Hz
129
014
010E
Mid. Output Frequency
0.1 to
399.9 Hz
0.1 Hz
1.5 Hz
(Note 8)
129
015
010F
Mid. Output Frequency
Voltage
0.1 to
255.0 V
0.1 V
12.0 V
(Note 2)
(Note 8)
129
016
0110
Min. Output Frequency
0.1 to
10.0 Hz
0.1 Hz
1.5 Hz
(Note 8)
129
017
0111
Min. Output Frequency
Voltage
0.1 to
50.0 V
(Note 2)
0.1 V
12.0 V
(Note 2)
(Note 8)
129