6. Operating with DeviceNet Communications
101
01
04
Pro-
duced
connec-
tion ID
Indicates the label
that is used in the
Inverter’s commu-
nications header.
These values are
set when the com-
munications con-
nection is
completed.
---
---
OK
---
Word
05
Con-
sumed
connec-
tion ID
---
---
OK
---
Word
06
Initial
comm
charac-
teristics
Indicates the
Inverter’s commu-
nications format
with a code.
---
21
OK
---
Byte
07
Pro-
duced
connec-
tion size
Indicates the maxi-
mum number of
bytes for transmis-
sions.
---
0014
OK
---
Word
08
Con-
sumed
connec-
tion size
Indicates the maxi-
mum number of
bytes for recep-
tions.
---
0014
OK
---
Word
09
Expect-
ed pack-
et rate
Indicates the time-
out time for inter-
nal processing
after a communi-
cations request
was received. (Set
in multiples of
10 ms.)
0 to
65,53
5 ms
09C4
(2,500 ms)
OK
OK
Word
0C
Watch-
dog tim-
eout
action
Indicates the ac-
tion to take when a
timeout occurred
during internal pro-
cessing related to
communications.
00: Maintain until
reset or discon-
nected.
01: Disconnect au-
tomatically.
02: Perform the
operation again
while connected.
---
01
OK
---
Byte
0D
Pro-
duced
connec-
tion path
length
Indicates the
transmission con-
nection path’s
number of bytes.
---
0000
OK
---
Word
0E
Pro-
duced
connec-
tion path
Indicates the appli-
cation object that
transmits data
from the instance.
---
---
OK
---
Array
0F
Con-
sumed
connec-
tion path
length
Indicates the re-
ception connection
path’s number of
bytes.
---
0000
OK
---
Word
In-
stance
At-
tribute
Name
Contents
Setting
Range
Factory Set-
ting (Hex)
Read Write
Size