1.4 Ratings and Specifications of a Multi-Winding Drive System
1-11
1
Outline
∗1.
Speed regulation is defined as follows:
∗2.
Set Pn001 to n.
2 if you will not use the dynamic brake.
(2) Basic Specifications of SERVOPACKs and Converters
Basic specifications of SERVOPACKs and converters are shown below.
∗1.
Set Pn001 to
2 in the multi-winding drive unit parameters if you will not use the dynamic brake.
∗2.
Implement risk assessment and confirm that the safety requirements of the machine have been met.
Regenerative Processing
Included.
External regenerative resistor units are required for the converters.
Overtravel Prevention (OT)
Dynamic brake stop, deceleration to a stop, or coasting to a stop at P-OT or
N-OT
Protective Functions
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error,
and so on.
Utility Functions
Gain adjustment, alarm history, JOG operation, origin search, and so on.
(cont’d)
=
×
100%
Speed regulation
No-load motor speed − Total load motor speed
Rated motor speed
Rotation
Drive Method
Sine-wave current drive with PWM control of IGBT
Operating
Conditions
Surrounding Air Tem-
perature
0
°
C to +55
°
C
Storage Temperature
-20
°
C to +85
°
C
Ambient Humidity
90% RH or less
With no freezing or condensation
Storage Humidity
90% RH or less
Vibration Resistance
4.9 m/s
2
Shock Resistance
19.6 m/s
2
Protection Class
IP10
The environment must satisfy the following conditions:
• Free of corrosive or flammable gases
• Free of exposure to water, oil, or chemicals
• Free of dust, salts, or iron dust
Pollution Degree
2
Altitude
1000 m or less
Others
Free of static electricity, strong electromagnetic fields, magnetic fields or
exposure to radioactivity
Harmonized Standards
Refer to
Harmonized Standards
in the preface for details.
Mounting
Standard: Base-mounted
Optional: Duct-ventilated
I/O
Signals
Sequence
Input
Fixed Input
DB answer (/DBANS)
Sequence
Output
Fixed Output
Servo alarm (ALM) output
LED Display
CHARGE, POWER, and COM indicators, one 7-segment LED
Dynamic Brake (DB)
*1
Included
An external dynamic brake unit is required.
Regenerative Processing
Included
An external regenerative resistor unit is required.
Protective Functions
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error,
and so on.
Utility Functions
Current detection offset adjustment and alarm history
Safety Function
*2
Input
/HWBB1, /HWBB2: Baseblock signal for power module
Output
EDM1: Monitoring status of internal safety circuit (fixed output)