9.1 List of Parameters
9-7
9
Ap
pend
ix
Pn00D
2
Application Function Select Switch D
0000 to 1011
−
0000
−
Setup
–
Pn081
2
Application Function Select Switch 81
0000 to 1111
−
0000
After restart
Setup
–
Pn100
2
Speed Loop Gain
10 to 20000
0.1 Hz
400
Immediately
Tuning
5.6.1
Pn101
2
Speed Loop Integral Time Constant
15 to 51200
0.01 ms
2000
Immediately
Tuning
5.6.1
Pn102
2
Position Loop Gain
10 to 20000
0.1/s
400
Immediately
Tuning
5.6.1
Pn103
2
Moment of Inertia Ratio
0 to 20000
1%
100
Immediately
Tuning
5.6.1
Pn104
2
2nd Speed Loop Gain
10 to 20000
0.1 Hz
400
Immediately
Tuning
5.6.1
Pn105
2
2nd Speed Loop Integral Time Constant
15 to 51200
0.01 ms
2000
Immediately
Tuning
5.6.1
Pn106
2
2nd Position Loop Gain
10 to 20000
0.1/s
400
Immediately
Tuning
5.6.1
Pn109
2
Feedforward Gain
0 to 100
1%
0
Immediately
Tuning
5.7.1
Pn10A
2
Feedforward Filter Time
Constant
0 to 6400
0.01 ms
0
Immediately
Tuning
5.7.1
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
Reserved (Do not change.)
Dynamic Brake Signal Selection
When Enabled
Reference
Section
0
Enables the control of an NO contactor
(The dynamic brake is activated when current is supplied to
the contactor coil.)
After restart
3.10.3
1
Enables the control of an NC contactor
(The dynamic brake is activated when current is not supplied
to the contactor coil.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
When Enabled
Reference
Section
0
Does not detect overtravel warning.
Immediately
4.3.2
1
Detects overtravel warning.
4th 3rd 2nd 1st
digit digit digit digit
n.
Reserved (Do not change.)
n.
Reserved (Do not change.)
0
1
Phase-C Pulse Output Selection
Outputs phase-C pulse only in forward direction.
Outputs phase-C pulse in forward and reverse direction.
Reserved (Do not change.)
4th
digit
3rd
digit
2nd
digit
1st
digit