3.3 I/O Signal Connections
3-17
3
Wirin
g and
Co
nnectio
n
(2) Output Signals
Note: The allocation of the output signals (/SO1 to /SO3) can be changed. For details, refer to
3.4.2 Output Signal Alloca-
tions.
Signal
Pin No.
Name
Function
Refer-
ence
Section
ALM+
ALM-
31
32
Servo alarm output
signal
Turns OFF when an error is detected.
−
/SO1+
/SO1-
/SO2+
/SO2-
/SO3+
/SO3-
25
26
27
28
29
30
General-purpose
output signal
Used for general-purpose output.
Note: Set the parameter to allocate a function.
−
/BK
/COIN
/V-CMP
/TGON
/S-RDY
/CLT
/VLT
/WARN
/NEAR
Can be
allocated
Brake control
Positioning comple-
tion
Speed coincidence
detection
Rotation detection
Servo ready
Torque limit
Speed limit detection
Warning
Near
The allocation of an output signal to a pin can be changed in
accordance with the function required.
−
PAO
/PAO
33
34
Phase-A signal
Encoder output pulse signals for two-phase pulse train with
90
°
phase differential
4.4.4
4.6.5
PBO
/PBO
35
36
Phase-B signal
PCO
/PCO
19
20
Phase-C signal
Origin pulse output signal
PL1
PL2
PL3
3
13
18
External latch power
supply
The power supply output for external latch signals.
–
TMON
16
Analog monitor 1
Analog monitor outputs.
–
VTG-M
17
Analog monitor 2
SG
1, 2, 6, 10 Signal ground
Connects to the 0 V pin on the control circuit of the host con-
troller.
−
FG
Shell
Frame ground
Connected to frame ground if the shielded wire of the I/O sig-
nal cable is connected to the connector shell.
−
−
4, 5, 9,
18
23
24
37 to 39
48 to 50
−
Do not use these pins.
−