9 Appendix
9.1.2 Parameters
9-10
Pn144
2
Model Following Control Bias
(Reverse Direction)
0 to 10000
0.1%
1000
Immediately
Tuning
−
Pn145
2
Vibration Suppression 1
Frequency A
10 to 2500
0.1 Hz
500
Immediately
Tuning
−
Pn146
2
Vibration Suppression 1
Frequency B
10 to 2500
0.1 Hz
700
Immediately
Tuning
−
Pn147
2
Model Following Control Speed Feedfor-
ward Compensation
0 to 10000
0.1%
1000
Immediately
Tuning
−
Pn148
2
2nd Model Following Control Gain
10 to 20000
0.1/s
500
Immediately
Tuning
−
Pn149
2
2nd Model Following Control Gain
Compensation
500 to 2000
0.1%
1000
Immediately
Tuning
−
Pn14A
2
Vibration Suppression 2
Frequency
10 to 2000
0.1 Hz
800
Immediately
Tuning
−
Pn14B
2
Vibration Suppression 2 Compensation
10 to 1000
1%
100
Immediately
Tuning
−
Pn14F
2
Control Related Switch
0000 to 0011
-
0011
After restart
Tuning
–
Pn160
2
Anti-Resonance Control Related Switch
0000 to 0011
−
0010
Immediately
Tuning
5.2.1,
5.4.1,
5.3.1,
5.5.1
Pn161
2
Anti-Resonance Frequency
10 to 20000
0.1 Hz
1000
Immediately
Tuning
−
Pn162
2
Anti-Resonance Gain
Compensation
1 to 1000
1%
100
Immediately
Tuning
−
Pn163
2
Anti-Resonance Damping Gain
0 to 300
1%
0
Immediately
Tuning
−
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
Model Following Control Type Selection
Reference
Section
0
Model Following Control 1
5.2.1,
5.3.1
1
Model Following Control 2
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Anti-Resonance Control Selection
0
Does not use anti-resonance control.
1
Uses anti-resonance control.
Anti-Resonance Control Adjustment Selection
0
Does not adjust anti-resonance control automatically using utility function.
1
Adjusts anti-resonance control automatically using utility function.
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.