4 Operation
4.1.1 Setting the MECHATROLINK-II Communications Switches (S1001 and S1002)
4-4
(2) Setting the Station Address
The following table lists the possible settings of the rotary switch (S1001) and the DIP switch (S1002) that can
be combined to form a station address.
The factory setting for the station address is 41H (Bit 3 of S1002 = OFF, S1001 = 1).
Bit 3 of S1002
S1001
Station Address
Bit 3 of S1002
S1001
Station Address
OFF
0
Disabled
ON
0
50H
OFF
1
41H
ON
1
51H
OFF
2
42H
ON
2
52H
OFF
3
43H
ON
3
53H
OFF
4
44H
ON
4
54H
OFF
5
45H
ON
5
55H
OFF
6
46H
ON
6
56H
OFF
7
47H
ON
7
57H
OFF
8
48H
ON
8
58H
OFF
9
49H
ON
9
59H
OFF
A
4AH
ON
A
5AH
OFF
B
4BH
ON
B
5BH
OFF
C
4CH
ON
C
5CH
OFF
D
4DH
ON
D
5DH
OFF
E
4EH
ON
E
5EH
OFF
F
4FH
ON
F
5FH
• Turn the control power supply OFF and ON again to validate the new settings.