6 Utility Functions (Fn
)
6-28
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using S while this function is being executed.
No : Parameters cannot be changed using S while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
7
To exit the EasyFFT function at this stage, press
the
Key. The power to the servomotor is turned
OFF and the display returns to the main menu of the
utility function.
To remeasure the vibration frequency, press
the
Key to return to step 4. Execute steps 5 to 7.
8
Press the
Key after the normal completion of
frequency detection. The notch filter frequencies are
automatically updated to the optimum values.
The status display shows "DONE" and the display
shown on the left appears.
If the first stage notch filter frequency has been set
(Pn408.0 = 1), the second stage notch filter frequency
(Pn 40C) will automatically be updated.
Notes:
• If the first stage or the second stage notch filter
frequency has already been set (Pn408
=
n.
1
1),
the notch filter frequency cannot be set.
• If the frequency detected by this function is not
used, set the notch filter to be invalid (Pn408.0
=
0).
9
Press the
Key.
The servomotor enters a baseblocked status. The
display returns to the main menu of the utility
function.
10
When you finish the EasyFFT operation, turn the control power supply OFF and ON again.
(cont’d)
Step
Display after Operation
Keys
Operation
B B
−
E a s y F F T
−
R e a d y
I n p u t = 0 1 5 %
D
㧻 㧺 㧱
−
E a s y F F T
−
R e s u l t
I n p u t = 0 1 5 %
R e s = 1 2 5 0 H z
F i l t e r 1 1 2 5 0 H z
B B
−
F U N C T I O N
−
F n 2 0 5 : V i b S u p
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V - M o n i t o r
F n 0 0 0 : A l m H i s t o r y
Parameter
Name
Mid-execution
changes
Automatic
changes
Pn408
Torque Related Function Switch
Yes
Yes
Pn409
1st Notch Filter Frequency
No
Yes
Pn40A
1st Notch Filter Q Value
No
No
Pn40C
2nd Notch Filter Frequency
No
Yes
Pn40D
2nd Notch Filter Q Value
No
No
Pn456
Sweep Torque Reference Amplitude
No
No