12.2 Magnetic Contactors
12-6
12.2
Magnetic Contactors
Use a Magnetic Contactor when you configure an external AC power supply sequence.
Note: Always attach a Surge Absorber (e.g., a Surge Absorber unit) to the excitation coil of the magnetic contactor.
Consult Fuji Electric FA Components & Systems Co., Ltd. for details.
Selection Table
Σ
-7S SERVOPACKs
Σ
-7W SERVOPACKs and
Σ
-7C SERVOPACKs
Main Circuit
Power
Supply
SERVOPACK
Order
Number
Inquiries
Maximum
Applicable Motor
Capacity [kW]
Model
SGD7S-
Three-phase,
200 VAC
0.05
R70A
SC-03
Fuji Electric FA
Components & Systems
Co., Ltd.
0.1
R90A
0.2
1R6A
0.4
2R8A
0.5
3R8A
0.75
5R5A
SC-4-1
1.0
7R6A
1.5
120A
2.0
180A
SC-5-1
3.0
200A
5.0
330A
SC-N1
6.0
470A
7.5
550A
SC-N2
11
590A
SC-N2S
15
780A
SC-N3
Single-
phase,
200 VAC
0.05
R70A
SC-03
0.1
R90A
0.2
1R6A
0.4
2R8A
0.75
5R5A
SC-4-1
1.5
120A
008
SC-5-1
Single-
phase,
100 VAC
0.05
R70F
SC-03
0.1
R90F
0.2
2R1F
0.4
2R8F
SC-4-1
Main Circuit
Power
Supply
SERVOPACK
Order
Number
Inquiries
Maximum
Applicable Motor
Capacity [kW]
Model
SGD7W-
SGD7C-
Three-phase,
200 VAC
0.2
1R6A
SC-03
Fuji Electric FA
Components & Systems
Co., Ltd.
0.75
2R8A
SC-4-1
0.75
5R5A
1.0
7R6A
SC-5-1
Single-
phase,
200 VAC
0.2
1R6A
SC-03
0.4
2R8A
SC-4-1
0.75
5R5A
SC-5-1