10.5 I/O Signal Cables for SERVOPACKs
10.5.2 For
Σ
-7S MECHATROLINK-II/-III Communications Reference or Command Option Attachable-Type SERVOPACKs
10
Cables and User
-Assembled W
iring Materials for SER
VOP
ACKs
10-19
Connector-Terminal Block Converter Unit
Selection Table
Dimensional Drawing
Dimensional Drawing of Enclosed Cable
Note: The same pin numbers are used for the SERVOPACK connector and the terminal block. Pins 1 to 26 are
wired. Do not connect pins 27 and higher.
To assemble your own cables, refer to the following section for the wiring specifications.
Order Number
Length of Enclosed Cable (L)
Inquires
JUSP-TA26P-E
0.5 m
Yaskawa Controls Co., Ltd.
JUSP-TA26P-1-E
1 m
JUSP-TA26P-2-E
2 m
40
39
1
2
B20
A20
B1
A1
29.5
20.5
15.5
45
2
7
7
43
3.5
202.5
3.5
2 × 3.5 dia.
holes
FCN-364P040-AU
Unit: mm
Can be mounted to DIN rail.
Connector Plug (40P)
M3.5 screws
Terminal block (40P)
73
47
39
L
37.2
AWG28, 18P
SSRFPVV-SB
Unit: mm
FCN-360C040-B (Fujitsu Ltd.)
Cover
FCN-361J040-AU (Fujitsu Ltd.)
Terminal Block Converter Unit connector (40P)
Cable (black)
10326-52A0-008 (3M Japan Limited)
Shell
10126-6000EL (3M Japan Limited)
SERVOPACK connector (26P)