9.2 Cable Configurations
9.2.3 Connections to Linear Encoder from Magnescale Co., Ltd.
9
Cable
s
and U
s
er
-A
ss
embled W
iring Material
s
for Linear
S
ervomotor
s
9-11
9.2.3
Connections to Linear Encoder from Magnescale Co.,
Ltd.
SL7
0 Linear Encoder and PL101-RY Sensor Head with
Interpolator
*1.
Cables to connect to the host controller are not provided by Yaskawa.
Refer to the following section for information on connector models.
*2.
Only SGLFW2 Servomotors come equipped with Thermal Protector Relay Connectors.
1. You cannot use a PL101-RY Sensor Head with an Interpolator together with a Linear Servo-
motor with a Polarity Sensor.
2. If you use an SGLFW2 Servomotor, input the thermal protector signal from the Linear Servo-
motor to the host controller. The thermal protector signal is closed when the temperature is
normal and open when the thermal protector is activated. Do not exceed 3 A or 30 V.
No.
Cable Type
Reference
Servomotor Main Circuit Cables
Encoder Cable
Important
Input to ho
s
t controller
*1
S
ERVOPACK
Main circuit
connector
CN2
S
ervomotor Main Circuit Cable
Encoder Cable
S
ervomotor
Main Circuit Cable
Moving
Coil
Magnetic Way
S
L7
0 Linear Encoder
from Magne
s
cale Co., Ltd.
Thermal Protector
Relay Connector
*2
Product
s
from
Magne
s
cale Co., Ltd.
PL101-RY Head with
Interpolator