![YASKAWA SGD7W Series Скачать руководство пользователя страница 188](http://html1.mh-extra.com/html/yaskawa/sgd7w-series/sgd7w-series_selection-manual_3716616188.webp)
9.2 Cable Configurations
9.2.1 Connections to Linear Encoder from Dr. JOHANNES HEIDENHAIN GmbH
9-6
SGLFW2 Servomotors
*1.
Only SGLFW2 Servomotors come equipped with Thermal Protector Relay Connectors.
*2.
When using a JZDP-J00
-
Serial Converter Unit, do not use a Yaskawa Linear Encoder Cable that is lon-
ger than 3 m.
*3.
Contact Dr. JOHANNES HEIDENHAIN GmbH for details on cables (analog 1 Vp-p output, D-sub 15-pin, male)
from Dr. JOHANNES HEIDENHAIN GmbH.
No.
Cable Type
Reference
Servomotor Main Circuit Cable
Serial Converter Unit Cable
Serial Converter Unit
Sensor Cable
Linear Encoder Cable
S
en
s
or Cable
S
ERVOPACK
Main circuit
connector
CN2
S
ervomotor Main Circuit Cable
Linear Encoder
Cable
*2
S
erial Converter
Unit Cable
S
erial Converter Unit
S
ervomotor Main
Circuit Cable
Moving
Coil
Magnetic Way
Linear Encoder from
Dr. JOHANNE
S
HEIDENHAIN GmbH
Cable from
Dr. JOHANNE
S
HEIDENHAIN GmbH
*3
Thermal Protector
Relay Connector
*1