Limits
Valid value range
Lower count limit
-2 147 483 648 (-2
31
)
Upper count limit
+2 147 483 647 (2
31
-1)
Main counting direction forward
n
The counter counts forward starting with the
load value
.
n
When the counter reaches the end value –1 in positive direction, it
jumps to the load value at the next positive count pulse.
Limits
Valid value range
Limit value
-2 147 483 647 (-2
31
+1)
to +2 147 483 647 (2
31
-1)
Lower count limit
-2 147 483 648 (-2
31
)
Main counting direction backwards
n
The counter counts backwards starting with the
load value
.
n
When the counter reaches the
end value
+1 in negative direction,
it jumps to the
load value
at the next negative count pulse.
n
You may exceed the upper count limit.
VIPA System SLIO FM 050
Deployment
Counter - Functions
HB300 | FM | 050-1BA00 | GB | 15-11