4
Deployment
4.1 Fast introduction
Limits
Valid range of values
Lower counter limit
-2 147 483 648 (-2
31
)
Upper counter limit
+2 147 483 647 (2
31
-1)
The maximum counter frequency is 400kHz.
At CPU, PROFIBUS and PROFINET the input respectively output
area is embedded to the corresponding address area.
IX - Index for access via CANopen
SX - Subindex (6000h + EtherCAT-Slot) for access via EtherCAT
More can be found in the according manual of your bus coupler.
Addr. Name
Bytes
Function
IX
SX
+0
CV_I
4
Counter value
5400h
01h
+4
CL_I
4
Latch value
5401h
02h
+8
CSTS_I
2
Counter status
5402h
03h
+10
C_US
2
µs ticker
5403h
04h
At CPU, PROFIBUS and PROFINET the output area is embedded to
the corresponding address area.
IX - Index for access via CANopen
SX - Subindex (7000h + EtherCAT-Slot) for access via EtherCAT
More can be found in the according manual of your bus coupler.
Addr. Name
Bytes
Function
IX
SX
+0
CC_I
4
Comparison
value
5600h
01h
+4
CS_I
4
Set value
5601h
02h
+8
CCTRL_I
2
Control word
5602h
03h
Bit
Name
Function
0
STS_SYNC
Reset was active
1
STS_CTRL_DO
Is set when digital output is enabled
2
STS_SW-GATE
Status software gate
(set when
SW
gate is active)
Counter range
Address areas
Input area
Output area
CSTS_I Counter status
VIPA System SLIO FM 050
Deployment
Fast introduction
HB300 | FM | 050-1BA00 | GB | 15-11
39