3
Data setting
3-16
4.2.3 Servo parameters
• Controller setting
TS-X
TS-SH
K74
Absolute setting
Setting Range
Default
Units
Restart
0 to 1
1
-
Required
Function
Sets the absolute function enabled or disabled.
Settings
Setting value
Description
0
Disable
1
Enable
• Adjustment
K76
Payload 1
Setting Range
Default
Units
Restart
0 to … (depends on robot type)
Depends on robot type
kg
-
Function
Specifies the maximum weight of objects (tools, workpieces, etc.) which can be mounted on the robot. Based on this
setting, the maximum acceleration (max. payload accel. 1 (K77)) for each robot type is automatically calculated and set.
w
WARNING
pAyloAD, ACCElERAtIoN, AND DECElERAtIoN SEttINGS WhICh DIffER GREAtly fRoM thE ACtuAl vAluES WIll RESult IN
opERAtIoN tIME loSS, ShoRtEN thE RoBot lIfE, AND CAuSE vIBRAtIoN. BE SuRE to SEt thEM to AppRopRIAtE vAluES.
TIP
For payload details, see section 7.4, "Changing the payload", in Chapter 5.
K77
Max. payload accel. 1
Setting Range
Default
Units
Restart
-
Depends on robot type
m/s
2
-
Function
Specifies the maximum payload acceleration defined by the "Payload 1" (K76) parameter. This is a "read only" parameter.
K78
Payload 2
Setting Range
Default
Units
Restart
0 to … (depends on robot type)
Depends on robot type
kg
-
Function
Specifies the maximum weight of objects (tools, workpieces, etc.) which can be mounted on the robot. The maximum
acceleration (max. payload accel. 2 (K79)) for each robot type is automatically calculated and set based on this setting.
w
WARNING
pAyloAD, ACCElERAtIoN, AND DECElERAtIoN SEttINGS WhICh DIffER GREAtly fRoM thE ACtuAl vAluES WIll
RESult IN opERAtIoN tIME loSS, ShoRtEN thE RoBot lIfE, AND CAuSE vIBRAtIoN. BE SuRE to SEt thEM to
AppRopRIAtE vAluES.
TIP
For payload details, see section 7.4, "Changing the payload", in Chapter 5.
K79
Max. payload accel. 2
Setting Range
Default
Units
Restart
-
Depends on robot type
m/s
2
-
Function
Specifies the maximum payload acceleration defined by the "Payload 2" (K78) parameter. This is a "read only" parameter.
• Stop mode
TS-S
TS-S2
TS-SH
K123
Stop mode setting
Setting Range
Default
Units
Restart
0 to 1
0
-
-
Function
Specifies the stop mode.
Содержание TS-S
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......