5
o
peration
5-32
Point data writing
n
Name
Command
Command Option
Command Response
WIN0
WIN1
WIN2, WIN3
WOUT1
WOUT2, WOUT3
Operation type write
0200h
Point No.
Operation type
Point No.
-
Position write
0201h
Point No.
Position data
Point No.
-
Speed write
0202h
Point No.
Speed data
Point No.
-
Acceleration write
0203h
Point No.
Acceleration data
Point No.
-
Deceleration write
0204h
Point No.
Deceleration data
Point No.
-
Push force write
0205h
Point No.
Push force data
Point No.
-
Zone (-) write
0206h
Point No.
Zone (-) data
Point No.
-
Zone (+) write
0207h
Point No.
Zone (+) data
Point No.
-
"Near width" write
0208h
Point No.
"Near width" data
Point No.
-
Jump write
0209h
Point No.
Jump data
Point No.
-
Flag write
020Ah
Point No.
Flag data
Point No.
-
Timer write
020Ch
Point No.
Timer data
Point No.
-
n
NOTE
• "Position", "speed", "acceleration", "deceleration", and "push force" writing occurs in the RAM. To save the data
to memory, the "operation type" must be written after writing each of these data items.
• The permissible point No. setting range at the command option is "1 (0001h) to 255 (00FFh)". When a command
is executed, a point No. answerback is returned to the command response (WOUT1).
Point data reading
n
Name
Command
Command Option
Command Response
WIN0
WIN1
WIN2, WIN3
WOUT1
WOUT2, WOUT3
Operation type read
0300h
Point No.
-
Point No.
Operation type
Position read
0301h
Point No.
-
Point No.
Position data
Speed read
0302h
Point No.
-
Point No.
Speed data
Acceleration read
0303h
Point No.
-
Point No.
Acceleration data
Deceleration read
0304h
Point No.
-
Point No.
Deceleration data
Push force read
0305h
Point No.
-
Point No.
Push force data
Zone (-) read
0306h
Point No.
-
Point No.
Zone (-) data
Zone (+) read
0307h
Point No.
-
Point No.
Zone (+) data
"Near width" read
0308h
Point No.
-
Point No.
"Near width" data
Jump read
0309h
Point No.
-
Point No.
Jump data
Flag read
030Ah
Point No.
-
Point No.
Flag data
Timer read
030Ch
Point No.
-
Point No.
Timer data
n
NOTE
• The permissible point No. setting range at the command option is "1 (0001h) to 255 (00FFh)".
• 2-word data is registered (Little Endian) at the command response (WOUT2, WOUT3).
Содержание TS-S
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......