7
Specifications
7-2
1.1.2
TS-X
TS-P
Item
100V AC input
200V AC input
TS-X105
TS-P105
TS-X110
TS-P110
TS-X205
TS-P205
TS-X210
TS-P210
TS-X220
TS-P220
Controllable robot
*1
TS-X: FLIP-X series
TS-P: PHASER series
Power capacity
400VA
600VA
400VA
600VA
1400VA
Dimensions
W58×H162×D131mm
W70×H162×D131mm
Weight
Approx. 0.9kg
Approx. 1.1kg
Control power supply
Single-phase
100 to 115V AC ±10%, 50/60Hz
Single-phase
200 to 230V AC ±10%, 50/60Hz
Main power supply
Single-phase
100 to 115V AC ±10%, 50/60Hz
Single-phase
200 to 230V AC ±10%, 50/60Hz
Control method
Closed loop vector control method
Position detection
method
TS-X: Multi-turn resolver with absolute position function (resolution: 16384 P/r)
TS-P: Magnetic linear scale (resolution: 1μm)
Operation mode
Positioning operation by specifying point number, Direct positioning command
Types of operation
Positioning, merge-positioning, push, and jog operations
Number of points
255
Point type setting
1) Standard setting : Set speed and acceleration in percent of the respective maximum settings.
2) Custom setting : Set speed and acceleration in SI units.
Point teaching
Manual data input (coordinate input), teaching, direct teaching
I/O interface
Selectable from the following: NPN, PNP, CC-Link, DeviceNet, EtherNet/IP.
Input
Servo ON (SERVO), reset (RESET), start (START), interlock (/LOCK), origin search (ORG),
manual mode (MANUAL), jog motion - (JOG-), jog (JOG+), point number selection (PIN0 to PIN7)
Output
Servo status (SRV-S), alarm (/ALM), operation end (END), operation in progress (BUSY),
control output (OUT0 - OUT3), point number output 0 to 7 (POUT0 - POUT7)
Communication
RS-232C, 1 channel
Power for brake
24V DC ±10%, 300mA (prepared by user)
Emergency stop
circuit
Emergency stop input, main power input ready output, emergency stop contact output (1 system: When the
HT1 is used.)
Protection function
Position detection error, power module error, overheat, overload, overvoltage, low voltage, position deviation,
over current, motor current error
Ambient operating
temperature and
humidity
0 to 40˚C, 35 to 85% RH (no condensation)
Storage ambient
temperature and
humidity
-10 to 65˚C, 10 to 85% RH (no condensation)
Atmosphere
Indoor, not exposed to direct sunlight. No corrosive gas, inflammable gas, oil mist, and dust particles should
be present.
Vibration resistance
10 to 57Hz in each of XYZ directions, single amplitude 0.075mm, 57 to 150Hz, 9.8m/s
2
Protective structure
IP20
*1. For "controlled robot" details, see section "1.2 List of controlled robots".
Содержание TS-S
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......