2
Installation and wiring
2-30
12.2 Circuit configuration examples
TS-S
TS-S2
TS-SH
Safety circuit configuration examples are shown below.
Customers should install the appropriate safety measures for their system by referring to these safety circuit
configuration examples in order to use the robots more safely.
12.2.1 Category 3
A safety circuit configuration example of category 3 is shown below.
S3
External
emergency stop
S2
Safety door
T2
T3
T2
Controller
Safety circuit
Power wiring
AC power
DC power
N
L
Earth
leakage
circuit
breaker
Noise
filter
Surge
absorber
Circuit
protector
AC/DC
Circuit
protector
Circuit
protector
S1
AUTO/MANUAL mode selection
MANUAL
MODE
a
b
AUTO
Close
Open
Close Open
+24V
a
b
G9SP
SRL1
V1,V2
G1,G2
O0
T2
T0
IN6
IN8
O1
IN0
IN2
IN3
IN4
IN5
IN1
T3
IN7
O2
Emergency stop Enable
E-STOP status
0V
MP24V
CP24V
FG
HT1-D
0V
24V
24V
DC IN
KM2
KM1
ES1
ES2
ES-
HT1-D
SAFETY
14
15
5
6
7
8
1
2
3
4
7
8
7
8
COM1
Category 3 safety circuit example
TS-S
TS-SH
TS-S2
23208-M3-00
Parts list
Circuit No.
Part name
Type No.
Manufacturer
S1
Key selector switch
A22TK series
OMRON
S2
Safety door switch
D4 series
OMRON
S3
Emergency stop button
A22E series
OMRON
KM1,2
Safety relay (linked contact)
G7SA-3A1B
OMRON
Socket for safety relay
P7SA-10F-ND
OMRON
SRL1
Safety controller
G9SP series
OMRON
Содержание TS-S
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......