32
En
Optimizing the speaker setting for your listening room
5
If you have finished the settings, press
9
l
to return to the previous menu level and then
press
9
n
to select “Start”.
6
Press
9
ENTER
to start the measurement.
This unit starts to count down from 10 seconds.
y
• To start the measurement immediately, press
9
ENTER
again.
• To cancel the automatic setup and return to the previous
screen, press
0
RETURN
.
Loud test tones are output from each speaker during
the measurement. Once all items are measured,
“Measurement Completed Successful” appears.
If an error or warning message appears, see “Error and
warning messages” (page 32).
7
Press
9
ENTER
to exit from the “Result”
screen.
y
• To view the measurement results in detail, press
9
h
.
Press
9
k
/
n
repeatedly to toggle between parameters
(page 35). Press
9
l
to return to the “Result” screen.
• To retry the measurement from step 4, press
9
k
.
8
Press
9
l
to save the measurement results
or
9
h
to discard them.
9
Press
I
MENU
to turn off the GUI menu and
disconnect the optimizer microphone.
■
Error and warning messages
If an error or warning message appears during the
automatic setup procedure, carry out one of the following
operations. For details on each message, see “Automatic
setup” (page 113).
• To view the details on the error and warning messages,
press
9
h
. Press
9
k
/
n
to display the previous/next
page (if available). Press
9
l
to return to the previous
menu level.
• To return to the GUI menu, press
9
l
.
• To retry the measurement, press
9
k
.
• To ignore the message and continue the process, press
9
n
.
Some operations cannot be performed depending on the type of
error (or warning).
Distance
(Speaker distance)
This unit checks and adjusts the distance of
each speaker from the listening position and
adjusts the timing of each channel.
Size
(Speaker size)
This unit checks and adjusts the frequency
response of each speaker and sets the
appropriate low-frequency crossover for
each channel.
Equalizing
(Speaker
equalizing)
Parametric equalizer adjusts the level of the
specified frequency bands. This unit
automatically selects the crucial frequency
bands for the listening room and adjusts the
level of the selected frequency bands to
create a cohesive sound field in the room.
Level
(Speaker level)
This unit checks and adjusts the volume
level of each speaker.
Before proceeding next operation
Once you perform the next operation, this unit starts the
automatic setup procedure in 10 seconds. During the
automatic setup procedure, do not perform any operation on
this unit. For more accurate measurements, we recommended
that you get out of the room or move to the wall where
speakers are not around during the measurement. It takes
approximately 3 minutes.
Note
Parameter
Descriptions
[ ]
Equalizing
Level
Result
Measurement Completed
Sucessful
Detail:
Exit:ENTER
Note
Pre Check
Main Check
Wiring
Retry
Exit
Detail
E0
9
:User Cancel