![wtw TresCon UNO A111 Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/wtw/trescon-uno-a111/trescon-uno-a111_operating-manual_1000694103.webp)
TresCon UNO
Operation
5 - 47
ba43134e08
05/2017
5.3.8
Relays as indicator contacts
If a relay is used as an indicator contact, a relay action is carried out
(
Open
,
Close
) if the monitored event occurs.
This function is suitable, e.g. for the monitoring of errors on the analyzer
modules. If an event takes place, the relay works as an indicator con-
tact.
Note
For monitoring functions, use the relay preferably as a normally closed
relay (see section 5.3.1). In the case of an error, the relay opens. As a
result, the monitoring function operates even if, e.g. the supply voltage
fails.
You can use the relay as an indicator contact for the following events:
Alarm: Lack of sample
Relay is activated if there is a lack of sample
Alarm: Container empty
Relay is activated if the container is empty
Alarm: Replenish container
Relay is activated if the fluid level in the container falls below 10 cm
Alarm: Malfunction
Relay is activated if a malfunction of any kind occurs
Measurement value valid
Relay is activated as long as the measured value is valid
Calibration running
Relay is activated when the analyzer module is in the calibration
mode
Measurement running
Relay is activated when the analyzer module is in the measuring
mode
Permeate state
If a permeate switch is installed, the relay is activated at the same
time as the three/two way valves of the permeate switch
Note
The messages, Lack of sample, Container empty/Fill container, can
only be output if the fluid level measurement and overpressure measu-
rement is active (see the M
AINTENANCE
chapter in the relevant sections
of the analyzer module in this operating manual).
Settings
Setting
Selection/Values
Explanation
Action
Normally closed
Normally open
Relay action (see
section 5.3.1)
Содержание TresCon UNO A111
Страница 2: ...2 ba43134e08 05 2017 TresCon UNO Copyright 2017 Xylem Analytics Germany GmbH Printed in Germany...
Страница 6: ...Inhaltsverzeichnis TresCon UNO 0 4 ba43134e08 05 2017 9 1 Abbreviations 9 1 9 2 Index 9 1...
Страница 18: ...Safety TresCon UNO 2 4 ba43134e08 05 2017...
Страница 56: ...Initial commissioning TresCon UNO 4 4 ba43134e08 05 2017...
Страница 133: ...TresCon UNO Operation 5 77 ba43134e08 05 2017 9 Select Yes or No with 68 and confirm with 3...
Страница 167: ...TresCon UNO Maintenance 6 11 ba43134e08 05 2017 6 Leave the menu with 4...
Страница 202: ...Appendix TresCon UNO 8 24 ba43134e08 05 2017...
Страница 207: ......