Manual – overview of system
office building)
11
Rush hour emptying building
Via internal time settings the haul capacity can be adapted ( typically
office building)
12
Dispatch waiting elevator
When all calls are executed after 1 min the elevators of a group are
distributed in the building; one is going to the main parking floor the
others remaining in different parking positions to reduce waiting time.
13
Interface to building control system
RS485 interface to link to PC for building control
14
Remote monitoring
The elevator can be integrated in an overall remote monitoring system.
15
Drive in Gong
During the landing approach a gong under the floor or over the ceiling of
the cabin informs about the arriving cabin.
16
Driving on displays HOP
In the hall indicator panels with an accoustic and optical display could
be integrated.
Floor gong
In every floor a Gong could be provided.
18
Card reader in the cabin
With a transponder card could either a specific call be released or
presetted calls be released
19
Card reader in the floors
Release of hall calls
20
Selective door control
Back-and frontdoor could be separated.
21
Push mode
After 1 min the door is closing slowly despite the light array.
22
VIP Service
A key switch in the HOP deletes all hall calls and brings the empty
cabine. Now several inside calls could be setted. After this the elevator
switches back in normal mode.
23
PIN entry via call button
For specific selection of floors the call buttons can be used to entry a
PIN
24
Floor activation locally controlled
For simple or duplex elevators an altered setting of floors can be entered
via key switch.
25
Floor activation via group control
Floor settings can be temporarily changed via groupannexe
Temporarily blockade from
individual floors
Floors could be blocked for short time from the user.
27
Automatic Evacuation
In case of a power failure with following emergency power supply the
cabin runs to the next floor
8
Emergency power evacuation
For elevator groups the evacuation is made one after another.
9
Earth quake Function
Elevator stops during run and brought to the evacuation stop.
30
announcement
Serial and parallel connection for announcements
Seite 6