Manual – overview of system
No.
name
description
Factory
setup
scope
F247
Protection option
of I²t
Overload prot via I²t Function:
0: both variations
1: Variation1 2: Variation2
0
0/1/2
F245=2 >> F246 bis F255 haben folgende Bedeutung:
F246 free
Internal use -do not change!
F247
PWM Modulation
mode
PWM Modulation
2
0~2
F248 free
Internal use -do not change!
F249 free
internal use -do not change!
F250
Three phase
current balance
coefficient
Only for your Info
F251 free
Internal use -do not change!
F252
Positive/Negative
rotation enable
enables right/ left rotation:
0: Both directions 1 only right direction
0
F253
Positiv/Negative
rotation dead time
Dead time for changing sense of rotation
20 x0.1s
20~60000
F254
Acceleration
overcurrrent
threshold of
inverter
The acceleration is limited if current exceeds the current
limit
180,00%
0~200
F255
Decelerating
overvoltage
threshold of
inverter
The deceleration is limited if tension in intermediate circuit
exceed limit
750V
0~800
F245=3 >> F246 to F255 as follows:
F246 Current Loop P
Current controller P-Factor, do not change!
140
35~280
F247 Current Loop I
Current controller I-Faktor, do not change!
100
25~200
F248 Current Loop D
Current controllerD-Faktor, do not change!
0
0~200
F254 Torque Direction
Torque Direction 0: pos; 1: neg
0
0/1
F245=4 >> F246 bis F255 as follows:
F246 Software Version
Only read
F247 ID No 0
Only read
F248 ID No 1
Only read
F249 ID No 2
Only read
Seite 66