Manual – overview of system
The adressing is made by DIL-switch or the floor button.
The SM04 is available in different designs: Horizontally, vertically and vertically-slim. The
diplays varies in design and circumference and can also be customized.
All SM04 can communiucate via CAN-bus and are combinable in any order.
In the floors on the SM04 Modulen (CAN-Modul) the push-buttons for the hallway calls
and the key-switch for special function. Newer panels permit also to connect a loudspeaker for the
EN81-70 required beep.
Special board SM09
Via those customized special functions could be realised without changing the control circuit. For
example the electronic electronic custodian system of the customer or additional fault-messages.
Functional overview
Standardfunctions
1
Group controllers
Collecting hall calls with respect to the given direction
2
Inspection run
Up or down. In the door zones the door open button can be used to open
the door.
3
Self liberation with slow drive
If you miss the door zone in normal mode the elevator drives slowly with
closed door into the levelling position and opens the door.
4
Testrun
For Testpurposes the elevator can make a determined number of random
testruns
5
Realtimeclock
Errors are registrated with date and time. Functions can be temporary
activated
6
Time to keep doors open
Dependant of the kind of call ( Interior, exterior, service, special call),
the time to keep the doors open can be indicated.
7
Door opening by local calls
Is the elevator allready in the floor from which the call comes, the door
opens.
8
Premature closing of the door.
With the door close button the door can be closed before the „Door
open-Time“.
9
Forced opening of doors
Inside the the door area with the door open button the door opening can
be forced for closed doors which are actually closed.
10
Return motion automatic
In case the cabin is not closed within 15 sec. after arrival at the door-
close endswitch, the door open again for a new try.
11
Monitoring of door opening
If 15 sec. After opening of the door the final door switch is not the door
closes for a new try.
12
Cancelling of call
Via double -CLICK of a call button the call can be cancelled.
13
Terminal landings
In the upper terminal the UP command is deleted; in the lower terminal
the down command is deleted.
14
Direct drive
Direct drive without rat run. Is activated when incremental copying and
analogue control. The travel curve at this will be created by the
controller,
15
Cabin Full
If full load, the cabinet do not stop anymore for hall calls
16
Cabin door light OFF
After 5 Minutes without activity the cabin light is switched OFF
17
Parking drive
After a ajustable time without activity the elevator drives into main floor
18
LCD control
Graphic display with extensive status information and menu navigation
19
Analogue speed setting.
The rotation frequency of frequency converter is guided by the analogue
output.
20
Digital speed inputs
Optional the speed can be set via contacts.
Seite 4