Manual-overview of system
No.
name
description
Factory
setup
scope
F56
UP levelling
adjustment
Fine tuning for stop UP: 50 for directrun, >100 for creep
run
50mm
0
~
240
F57
Down levelling
adjustment
Fine tuning for stop DOWN:0 for directrun, >100 for creep
run
50mm
0
~
240
F58
free
F59
Zero speed brake
delay
Delay beween inverter STOP command and brake
contactor OFF
0,00s
0~10.00s
F60
free
F61
Gong Output delay Arrival distance for arrival gong
1200mm
0
~
4000
F62
Anti-slipping time
limit
Time for anti-slipping
32s
2
~
45
F63
free
F64
free
F65
Base Block Mode
Block: 0- no block, 1- block, when motor contactor
deactivates
0
0-1
F66
Limit Mode
0
0
~
65535
F67
Additional board
Activating for add. Boards for main board
0
0
~
65535
F68
free
F69
free
F70
Idle reg. UP
Empty load compensation direction UP
100,00%
0.1~99.9
F71
Idle reg. Down
Empty load compensation direction DOWN
100,00%
0.1~99.9
F72
Full load reg. UP
FULL load compensation direction UP
100,00%
0.1~99.9
F73
Full load reg.
Down
FULL load compensation direction UP
100,00%
0.1~99.9
F74
Empty load reg
512
0
~
65535
F75
Full load reg.
512
0
~
65535
F76
Lim. UpDis. Ins.
0cm
0
~
65535
F77
Lim. DnDis. Ins.
0cm
0
~
65535
F78
Endswitch M.
F79
Insp. ES Mode
Moving of cabin beyond end switch for insp. (Test
Endswitch & traction)
0: no
1: enabled
0
0~1
F80
Door quitt. Mode
Setting button beep and flashing for call buttons
Bit 1: button-beep
Bit 2: flashing from cabin call when arrival
Bit 3: flashing of hall callt
Bit 4 beeping when passing floor for blind people
0
0~15
F81
Bright dark mode
Brightness of confirmation for cabin -&hall call if not
acknowleged: The lower 4 Bits define the brightness of
outside/ hall acknowledgements, the other 4Bits the
brightness of cabin confirmations
there are 9 grades of brightness.
0
0~255