Manual-overview of system
No.
name
description
Factory
setup
scope
F187 CAN Monitor
Status Überwachung
0
:
run counterer
1
:
malfunction of encoder
2
:
CAN-Bus 1 malfunction
3
:
CAN-Bus 2 malfunction
4
:
revolution RPM
5
:
tension intermediate circuit
6
:
output current motor
7
:
Torque
0
~
7
F188 free
F189 free
F190 floors 49-64
Floor permission 49-64
65535
0
~
65535
F191 A-door49-64
Permission door A at floors 49-64
65535
0
~
65535
F192 B-door 49-64
Permission door B at floors 49-64
0
0
~
65535
F193 free
F194 free
F195 free
F196
2. main landing
duplex control
2. main stop at duplexx
1
~
48 (64)
F197 free
F198 free
F199 NS-Etage 49-64
Blockable floor bitmask 49-64
0
~
65535
F200 SW Version
Software Version of inverter
x
F201 Inverter
Inverter modes:
0: V/F Mode
1: Vector Mode without encoder (only test)
2: torque mode with encoder
3: Vector Mode with encoder
3
0~3
F202 Motortype
Motor-Type
0: Asynchronous motor
1: Synchronous motor
0
0
~
1
F203
Nominated motor
power
Nominated motor power
x
0.4~160kW
F204
Nominated motor
current
Nominated motor current
x
0.0~300.0A
F205
Nominated motor
frequency
Nominated motor frequency
50Hz
0.0~120.0
F206
Nominated motor
revolution
Nominated motor revolution
1460RPM
0~3000
F207
Nominated motor
tension
Nominated motor tension
380V
0~460
F208 Motor pole number Motor pole number
4
2~128
F209
Motor slip
frequency
Motor slip frequency
1.4Hz
0
~
10.00
Seite 63