Manual – overview of system
No.
name
description
Factory
setup
scope
F28
Input Type HX0-15
Car roof input type (normal open or close setup for
HX0~HX15)
0
~
65535
F29
Service floor0-16
Setup if 1~16 floors are secure
0
~
65535
F30
Service floor 17-32 Setup if 17 – 32 floors are secure
0
~
65535
F31
Service floor 33-48 Setup if 33 – 48 floors are secure
0
~
65535
F32
free
F33
Number interv.
Automatic operation interval for testruns
0: no test runs
5s
0
~
65535
F34
Number testruns
Time between calls for test runs (random calls)
0: no function
0
0
~
65535
F35
Firefighting switch
Firefight input switch defintion and firefight mode selection
EN81-71 fire control
2
:
without key in cabin
3
:
with key in cabin
Pubel (RUS) firecontrol (russian)
4
:
without key in cabin
5
:
with key in cabin
0~5
F36
Brake switch M.
Standby time for brake monitor switch
0
:
no brake monitoring
1 : Standard brake monitoring
2 : Hongkong Version
1
0
~
2
F37
Password 1
Password 1
F38
Password 2
Password 2
F39
Password 3
Password 3
F40
load Offset
Load data bias
50.0%
0.1~99.9
F41
Load larning
Load study and parameter setup
0
-
F42
free
F43
Attendant mode
Flashing function selection for attendant status call
3
-
F44
RS485 Adress
Adress for remote monitoring via 5 network:
255 for non-monitor
255
0
~
255
F45
free
F46
free
F47
free
F48
free
F49
EVA-Mode
Emergency levelling orientation mode
0
0~2
F50
A-door 1-16
Front door opening permission floors 1~16
65535
0
~
65535
F51
A-door 17-32
Front door opening permission floors 17-32
65535
0
~
65535
F52
A-door 33-48
Front door opening permission floors33-48
65535
0
~
65535
F53
B-Door 1-16
Rear opening permission floors 1-16
0
0
~
65535
F54
B-door16 -32
Rear opening permission floors 17-32
0
0
~
65535
F55
B-door 32-48
Rear opening permission floors 33-48
0
0
~
65535