Manual – overview of system
No.
name
description
Factory
setup
scope
F210 Type of encoder
Type of encode
0: ABZ Incremental encoder
1: Sin Cos absolute encoder (Synchronous motors)
2 En-dat absolut encoder ( Synchnronous motors)
2
0~2
F211 Encoder impulse
Encoder impulseper turn
1024
500~16000
F212 P0-Factor
P-Factor encoder at Zero RPM
130.00
0.00~655.35
F213 I0-Faktor
I-Factor encoder at Zero RPM
80.00
0.00~655.35
F214 D0-Factor
D0Factor encoder at Zero RPM
0.50
0.00~655.35
F215 P1-Factor
P-Factor encoder at low RPM
130.00
0.00~655.35
F216 I1-Factor
I-Factor encoder at low RPM
80.00
0.00~655.35
F217 D1-Factor
D-Factor encoder at low RPM
0.50
0.00~655.35
F218 P2-Factor
P-Factor encoder at average RPM
130.00
0.00~655.35
F219 I2-Factor
I-Factor encoder at average RPM
80.00
0.00~655.35
F220 D2-Factor
D-Factor encoder at average RPM
0.50
0.00~655.35
F221 P3-Factor
P-Factor encoder at high RPM
130.00
0.00~655.35
F222 I3-Factor
I-Factor encoder at high RPM
80.00
0.00~655.35
F223 D3-Factor
D-Factor encoder at high RPM
0.50
0.00~655.35
F224 Freq. 0
1.0%
0~100%
F225 Freq. 1
50.0%
0~100%
F226 V0-Stoptime
0.5s
0.0~30.00
F227
Delay brake
monitor
Delay time for brake mon switch
0: no brake monitoring
0.25s
0.0~30.00
F228 Output current
0.00s
0.0~10.00
F229
Direction of
rotation
0: positive direction
1: negative direction
0
0/1
F230
Torque
compensation
100.00%
0.0~200.0
F231 Torque bias
0.0%
0.0~100.0
F232 Ecoder filter time
0ms
1~30
F233 Encoder direction
Direction of rotation from encoder always at 1 if motor
doesn't turn change phase of motor!
1
0/1
F234 Motorphase
Adaption of direction of rotation motor, if it doesn't match
with UP/DOWN cabin
1
0/1
F235
Empty load current
value
Empty load current value
32.00%
0.00~60.00
F236 Pace freq.
Frequency of output current
6.000kHz
1.100~11.000
F237 Modul. bandwidth
Modulation bandwidth don't change!!
0kHz
0.0~1.0
F238 Regulator Mode
Regel. Mode don't change without reason
1
0~3
F239 Torque.Lmt
Torque limit, don't change without reason
175,00%
0~200
F240 Input tension FU
Input tension of inverter
380V
0~460
F241 Nominal powerFU
Nominal power of inverter
x kW
-
Seite 64