Manual – overview of system
In a 2-second pulse the value of choosen parameter is depicted.
When pushing up/ down button the individual parameters are selected.
A change is enabled by pushing enter. Again enter confirms value.
Checking parameters for commissioning and eventually adapt
Normaly the parameters are set in the factory at the test field.
Since there are three 3 makes and several power class used, it is possible that the pre-set
values are inappropriate. Is there another drive than Sassi or Torin in use or the speed is other
than 1m/s please imperativly check the parameters!
Par.
name
Function
Setting
Remark
F06
Speed
Rated speed
1,0m/s
Attention! If a motor asigned for 1m/s is
driven with 0,63m/s , rated frequency
(hz) and rated revolution (RPM) has to
be reduced correspondantely!
F12
Insp. speed.
inspectionspeed
0,25m/s
F16
Braken open
redardation.
Retardation -Brakeopen
0,2s
F17
FU enable. retardation
Time for brake come-in
compensate
0,5s
Could be considerably longer for Swiss
Traction
F25
Input TypeX0-15
Input logic (NO/NC) input
AS 380 main board
Normally presetted; for commissioning
the inputs of pre-endswitsch should be
(X4,5,18 und 19) als NO (closing
contact,normally open)
F26
Input TypeX16-25
F36
Brake switch M.
Brake monitoring
0
Brake monitoring should be inactive as
long as brakeswitch is not connected.
Seite 20