Manual – overview of system
Checking of effectiveness from „DKU“
Unlock one of the monitored doors. Opening the door is not neccessary.
Now the elevator should not move neither by call or return-run button.
After apply of SSR at service Panel the elevator should move.
Repeat this check for every door under surveillance of DKU.
Simulation of „sticking“ Reset button
Hold the SSR pushed. The elevator should not move in normal mode or return move.
After release the elevator should move .
Check of the Inspection control
Attention Imperatively respect the following:
Allways set emergencvy stop before entering shaft or cabinceiling. This avoids accidents if test comes out
negativ..
Move the elevator with return move in one floor so that you could enter the cabintop.
If applicable erect the fold support in the fosse into protect position.
Now the elevator should move with the inspection control on the top or in the fosse.
Shut down the inspection, leave the fosse and keep the fold support in position.
Check Reset only possible with nonactive folded support
Try to reset DKU when door is closed.. this shouldn't be possible, means elevator cannot move -
not in normal mode or return move.
When there is no shortened fosse the reset could be made when closing all shaft doors.
Put now back the fold support in normal mode position. Protected area deactivated..
Leave the fosse and close shaft door(s).
final check
the elevator should not move-not in normal mode nor in return mode.
Actuate SSR. Now the elevator should move..
Seite 50