Manual – overview of system
Code
display
error
Remarks
targeted speed.
25
free
26
free
27
Up level Sw. Err
Sensor up levelling defectous
28
Dn level Sw. Err
Sensor down levelling defectous
29
free
30
Leveling Err
actual value of leveling signal is
/- than 180mm .
Position of levelling magnet is bigger than +/-
180mm .
→
new learning movement
necessary!
31
free
32
Safe loop broken
Safety loop is not closed
33
free
34
KMC Protection
K1 monitoring reports error
Output Y2 doesn't correspond with Input X8
35
KMC Protection
K8 monitoring reports error
Output Y2 doesn't correspond with Input X9.
36
KMC Protection
K2 monitoring reports error
Output Y2 doesn't correspond with Input X8.
37
Dr. Lock Error
Only relevant for asia
38
Brake Sw. Err
Brake switch monitoring reports
error
Brake contactor active, but brake is not
activated brakes don't work synchronous
(X22,X23).
39
Safety Relay Err
Security loop is controlled
addionally on Input X13 via relay.
X13 and high voltage inputs differ.
(note Parameter F156)Only
relevant for Asia
Safety Circuit input signal differ from safety
circuit relay detection signal X13. (look
Parameter F156). Only for Asia
40
Inv Enable Err
Inverter enable monitor detects
error
Signal for depr brake there-no inverter run
signal!.
41
free
42
Slow'down Sw. Err
Number of installed correction
switches does not correspond with
set parameters.
43
Limit test err.
44
free
45
Relvl Relay err
46
free
47
free
48
free
49
Invert comm. Err
Communication error between
inverter and car top panel
50
Parametererror
parameter read error
Seite 70