Manual-overview of system
21
Error storage
'the last 20 errors are stored with time, floor no and error code
22
Learning movement for shaft infos
The control learns via encoder and the floor flags the shaft measurements
and braking distances. After this the elevator can drive in normal mode.
23
Clearance of floors
Setting of floors which can be reached.
24
Setting of floor indicator.
The signs which appears in each floors can be selected
Liftboy control
The elevator is driven manually via car controller panel. Hall calls are
served.
26
Priority inside
Hall calls are deactivated. Only inside commands are effective.The door
had to be closed by door close button. The button has to be pushed until
door close final switch is reached.
27
LED-dot matrix display,
LCD graphic display
In each floor is a dot matrix display which indicates floor stand, direction
and status. The user can see wether something is going on.
28
Display with roll funbction
According to the drive direction the display is rolling.
29
Automatic correction of shaft datas.
The shaft informations are continously corrected..
30
Remote deenergisation
The elevator can be disengaged at which all ongoing car/ cabin
commands are executed prior to shut off..
31
Door is only opening in door zones.
Out of the door zones the the cabin door cannot be opened.
32
Light barrier/ light curtain
Light barrier/ light curtain is evaluated by control and prevent door
closing if activated
33
Overload
When overloaded the door remains open and buzzer is going on.
34
Misuse detection
If cabin is empty the cabin calls are limited.
35
Direction of rotation
Is a wrong direction of rotation is detected elevator stops.
Route monitoring
Is the cabin not moving despite active drive the drive stops after 40 sec.
New runs only after reset possible.
37
Monitoring traction
Is cabin moving despite stop od drive alarm is engaged.
Limit switch inspection run
Limit switches prevent that elevator is running into emergency limit
switches during learning movement or bring-back run.
39
Contractor monitoring
This control checks during every run the function of main and brake
contactors.
40
Speed monitoring
When overspeed >emergency stop!
41
CPU Monitoring
The processor is monitored via watchdog and restarted if necessary.
Optional functions
1
Preopening doors
Via safety circuit
2
Fine levelling with open door
Via safety circuit. For hydraulic standard function
3
Fire control system
When fire signal run elevator in fireman floor and stays with open door.
Fireman control
All commands are dropped and the elevator runs into fireman floor. Now
the firemen can use elevator.The doors doesn't open automatically but
has to be opened with door open button. Release of button actuates
immediate closing-european (EN81) und russian (PUBEL) option
5
2
nd
car controller panel
A second car controller panel can be easily fixed.
6
Car controllerpanel for 2. door
selective door control
7
Handicap panel
Own panel (eg desk panel) for handicaped people longer door open time
8
Duplex-Function
Via 2
nd
CAN-Bus two elevator can be connected to a 2group-system.
The elevators share the calls correspondant the actual situation in order
to reduce the waiting time to a minimum.
Addionally a function could be activated which brings the nearest
elevator to the parking level to dispose him (waiting).
9
Groupfunction
In an optimal control up to 8 elevators can be combined to a group.
The group control collect the hall calls and dispatches correponding the
actual location of the elevators to reduce finally the waiting time to a
minimum.
10
Rush hour filling building
Via internal time settings the haul capacity can be adapted ( typically
Seite 5