Manual – overview of system
operation:
In normal case the state, the group affiliation, actual floor, actual
speed and the actual state of doors or drive
The number in the 2
nd
line depicts the counter of runs can also be
setted for another value.
Log in:
To see the state or to set parameter you have first to login. After
pushing the ENTER button appears the password. Standard for the
Password „1234“. After login under Chg.Password“ the password could be
changed.. Attention! Don't forget Password! The control can be unlocked only in
the fatcory without Password!
Menu
The complete menu tree you'll find under „ Menu tree & parameter.
The Startwindow shows state, group affiliation, actual floor, actual speed and the
actual state of doors or drive.
With „ Enter“ you're going to main menu. Again Enter select Monitor-Menu,
which has all diagnosis windows.
State menu under „Monitor“
Run State conforming to the start
In the first line you see mode (Normal, Inspection, Fire Return, Firemen, Park)
and state of group (Simplex, Group).
Below counter of runs, Floor, speed and the actual action.
In Call. Func. The actual calls are depicted and you can also set calls (with the
arrow up/ dwn and Enter).
Cabin calls, hall calls up and down.
Speed Curve is the graphic depiction from speed encoder.
Above the actual speed and running time is indicated.
In the window Input&Output all inputs and outputs are depicted.
With the up/dwn buttons youre switching between the 16er groups.
With right/left a single input/ outout could be marked. In the line below
appears the function of this input/ output.
The designation X (Input SM01) and Y (Output SM01), plus TX (Input
SM02) and TY (Output SM02) you'll find in the electrical circuit.
Seite 8
Startwindow
Login