Manual
iAStar AS380
frequency converter with integrated lift control
system
Version E2.0 (MAI)
Страница 1: ...Manual iAStar AS380 frequency converter with integrated lift control system Version E2 0 MAI...
Страница 2: ...ng Installation run 17 Condition for commissioning run 17 Groupfunction 18 Security loop Return motion control 18 First movement with the Return motion control 18 Setting the parameters on AS T030 18...
Страница 3: ...Monitoring of run 46 CHECK 46 13 Advice of acceptance test 47 Generally 47 Isolation measurement 47 Check of run time monitoring 48 End switch movement 48 Effectiveness of the brakes one sided brake 4...
Страница 4: ...all types of lifts Lifts from 0 1m s to 10m s Up to 64 stops 2 group cluster integrated up to 8 in one group with group controller prepared for call control shaft copying by shaft encoder and magneti...
Страница 5: ...lot of special functions which are normally allocated in the shaft or engine room It communicates via the CAN Bus with the other modules Car controller panel SM02 All functions which are related to t...
Страница 6: ...al call the time to keep the doors open can be indicated 7 Door opening by local calls Is the elevator allready in the floor from which the call comes the door opens 8 Premature closing of the door Wi...
Страница 7: ...rive stops after 40 sec New runs only after reset possible 37 Monitoring traction Is cabin moving despite stop od drive alarm is engaged Limit switch inspection run Limit switches prevent that elevato...
Страница 8: ...lls be released 19 Card reader in the floors Release of hall calls 20 Selective door control Back and frontdoor could be separated 21 Push mode After 1 min the door is closing slowly despite the light...
Страница 9: ...ck select from error storage In Out display CAN and shaft encoder F3 Quick select graphic drive curb Next Parameter menupoint Increase of choosen decimalplace Jump back 10 parameters one decimal point...
Страница 10: ...ng to main menu Again Enter select Monitor Menu which has all diagnosis windows State menu under Monitor Run State conforming to the start In the first line you see mode Normal Inspection Fire Return...
Страница 11: ...tual then the existing one To set parameter in the submenu Para Select Via the parameter menu you can acceed on numerous parameters There are groups of parameters where the parameters are thematically...
Страница 12: ...Display codes are stated in a chart in the appendix Service Floor determines the enabled floors Also the floors which are only enabled by key switch are determinded Block Floor permits blocking of a...
Страница 13: ...inlight has to work correctly After activating of shaft teaching the elevator runs in the lowest stop and starts with the learning movement After finish the elevator can go into normal mode If an erro...
Страница 14: ...e limit switch Self diagnosis CAN Com Eval Diagnosis of CAN interfaces Encod Eval Analysis of encoder Call diagnosis Version Depiction Software Version Para Type Basic Param Basic Parameter Comfort Ad...
Страница 15: ...mber of random testruns Load adjust Load teach Load Status Door operate Reset Reset Errcode Reset error record Reset LiftP Reset Steeringparameter on factory setting Reset Inv FU Pa Reset Inverter par...
Страница 16: ...NO normally open NC normally closed Depends on the circuit and the connected switch Bitmask F26 83 F27 835 F28 0 F202 1 Type of motor 1 Synchron Motor F203 4 7kW Ratet motor power F205 29 4 Hz Rated...
Страница 17: ...50 00 F195 50 00 Comfort Adjust PI Adjust Nr Wert Beschreibung Hinweis F212 40 ASR P0 PID Parameter during start up Stop Zero Servo F213 60 ASR I0 F214 0 5 ASR D0 F215 40 ASR P1 PID Parameter for the...
Страница 18: ...away bracket in the security space and the folding support At X88 on Servicepanel measurement in the security loop could be executed Condition for commissioning run Drive Control cabinet service panel...
Страница 19: ...e range of the doors or in the shaft At first connect all existant security switches and elements If this is not possible the relevant strapping plugs should be placed First movement with the Return m...
Страница 20: ...e 4 digit password could be entered By pushing the up down arrow you set the number by pushing left right the ciphers are set The cipher is blinking in a 1 sec pulse Password 1234 The authorization fo...
Страница 21: ...he parameters Par name Function Setting Remark F06 Speed Rated speed 1 0m s Attention If a motor asigned for 1m s is driven with 0 63m s rated frequency hz and rated revolution RPM has to be reduced c...
Страница 22: ...ous Motor F203 M Rated Power Rated motor power 4kW This are values for Torin at 630kg 1m s At 0 63m s result a frquency of 16 67Hz at a revolution of 100RPM In any doubt check type plate F204 M Rated...
Страница 23: ...g parameters has proved workable especially for Torin motors For SWISS traction motor the values could be set considerably lower Nr Parameter Funktion Typ Hinweise F212 ASR P0 P Factor speed controlle...
Страница 24: ...rts doors open and the security loop is closed This error blocks the elevator To avoid this during installation you keep first the CAN Bus away Door open end switsch is first reported from SM02 H in t...
Страница 25: ...oder pulses eg 150U min at 2048ppr becomes 600U min 4 und 512 ppr When the encoder is mounted in the shaft circumferential cord for the rated revolution speed a equivalent revolution speed has to be s...
Страница 26: ...tops in case of error blackout of incremental encoder and for learn trip They are also used for correction of the incremental encoder datas In the set of drawings page 50 you can find these respectivl...
Страница 27: ...ailable as IP54 version which is used in firefighter lifts The solenoids are flat solenoids with 15mmx7mm of cross section and a variable length The solenoids are installed at the button of the arrest...
Страница 28: ...ling position outside KU KO Input designation X4 X5 X6 X7 X18 X19 LED at AS T030 In control parametrised as levator in highest leveling position within KO Input designation X4 X5 X6 X7 X18 X19 LED at...
Страница 29: ...agnet north Polarity North or South means the pole which shows to the sensor South is marked with white Reference point floor level shortmagnets length 20mm longmagnets length 150mm short magnet south...
Страница 30: ...1 1 Nx1 Neutral wire main contactor from supply line 110V 230VAC scan optocoupler VDE EN81 2 X20 Scan emergencysection of safety loop 3 X21 Scan end of safety loop 4 X22 Scan revolving door contacts 5...
Страница 31: ...ignal 2 Inspection OFF or normal mode input N 3 X2 Inspection return motion UP input N 4 X3 Inspection return motion DOWN input N 5 X4 Delay switch upwards up input N 6 X5 Delay switch downwards down...
Страница 32: ...Manual overview of system Terminal Name Description Function Advise JP10 1 24V 24V internal 2 COM Reference mass for optocoupler 3 GND Reference mass for control Seite 33...
Страница 33: ...rive In gong down Output TU 4 GND GND 5 24V 24V JP4 1 COM COM for HX0 HX1 2 HX0 End switch door open door A Input N 3 HX1 End switch door close door B Input N 4 COM common for HY2 HY4 5 HY2 Scrambling...
Страница 34: ...put TN 4 D3 Voice announcement bit3 Output TN 5 D4 Voice announcement bit4 Output TN 6 D5 Voice announcement bit5 Output TN 7 D6 Voice announcement bit6 Output TN 8 D7 Voice announcement bit7 Output T...
Страница 35: ...ion switch door B Output relay 4 COM COM for HX7 HX9 Output relay JP4 1 HX10 Light grid door B Output relay 2 HX11 free Output relay 3 COM COM HX10 HX11 Output relay JP5 1 HX12 free Output relay 2 COM...
Страница 36: ...Button door keep OPEN HOLD Input N 2 GX1 Special function Input N 3 GX2 Priority inside Input N 4 GX3 free Input N 5 GX4 Firedepartement control key switch Input N 6 COM COM 0V GX0 GX4 JP6 1 TY LED Do...
Страница 37: ...FF ON OFF OFF Idicator board B selective door OFF OFF ON OFF Desk indicator board OFF OFF OFF ON Additional indicator baoard SM03 button module Up to eight SM03 each for 8 buttons up to 64 floor butto...
Страница 38: ...ent can be different 4 Hall Call Upward Outout NPN 5 Continued travel arrow downwards Outout NPN 6 Continued travel arrow upwards Outout NPN JP10 1 24 for button COM Assignment can be differen for spe...
Страница 39: ...ould be connected with binary assignemt and common anode Set SW 2 1 to ON 4 5V output max 50mA 6 24V output max 50mA 8 10 A0 Output NPN 12 A1 Output NPN 14 A2 Output NPN 16 A3 Output NPN 18 A4 Output...
Страница 40: ...itch 5 4 3 2 1 6 7 8 switch for foldable gate optional S53 insp down insp up JP4 2 JP4 1 Y FR S17 S20 S26 final limit down S27 X11 1 2 Speed governor final limit up K9 SM11 Nx S500 S501 21 22 S502 A1...
Страница 41: ...compare the datas and respectivley make it possible to by pass the door contacts within the door zones or not For instance it should be attained the security of a castor security switch The security c...
Страница 42: ...ctuating anymore At the next run K10 is not actuating anymoreLift make stop opening door EMERGENCY STOP According to EN81 14 1 1 one single error do not lead to a dangerous operating conditon and will...
Страница 43: ...ircle the security contactore sources their controller voltage directly out of the security circle The security contactors motor contactors K1 and K2 as well the brake contactor K8 are seperatly monit...
Страница 44: ...on as the shaft copying isn t completly engaged set bith values on 0 within the doorzone with AUF Zu button the function of the doors could be checked Otherwise during inspection run doors are always...
Страница 45: ...it 1 to allow an overrun over the virtual end switches Send elevator in normal mode into uppermost and lowermost floors For this activate in menu Commissioning Test Menu Up Limit Test or Dn Limit The...
Страница 46: ...somebody is hurt if he entered the shaft without stopping the elevator by the emergency stop If he had entered and the door is closing behind him giving free the elevator When there is a short fosse...
Страница 47: ...es out negativ Move the elevator with return move in one floor so that you could enter the cabintop If applicable erect the fold support in the fosse into protect position Now the elevator should move...
Страница 48: ...zards by electrical strokes via the mecanic crushing cropping etc and furthermore hazards through the design drop fall etc Important do not only think at you but on people which could be in the danger...
Страница 49: ...opening from the shaftdoor If the elevator trundles away more than 2m the test has to be aborted Functional check Version B with inverter via check menu these procedure is designated for cable elevato...
Страница 50: ...ntactor Response time Brake Tb 200ms dependant of the used brake average deceleration 2000mm s2 dependant of the used brake calculation of time until doorzone is left detection time leaving doorzone T...
Страница 51: ...Manual overview of system Supplemental documents verification certificate SM011B circuit plan with AS380 Seite 54...
Страница 52: ...15 Closing delay2 Response to hall call 3 0s 0 30 0 F16 Brake delay Delay between FU Run Signal and Brake contactor on 0 2s 0 2 0s F17 Automatic enable signal release time Delay between brake contacto...
Страница 53: ...ch M Standby time for brake monitor switch 0 no brake monitoring 1 Standard brake monitoring 2 Hongkong Version 1 0 2 F37 Password 1 Password 1 F38 Password 2 Password 2 F39 Password 3 Password 3 F40...
Страница 54: ...direction UP 100 00 0 1 99 9 F71 Idle reg Down Empty load compensation direction DOWN 100 00 0 1 99 9 F72 Full load reg UP FULL load compensation direction UP 100 00 0 1 99 9 F73 Full load reg Down FU...
Страница 55: ...med on the handtool F84 0 No confirmation need 0 0 1 F85 Taxi Steuerung F85 0 deactivated F85 1 activated 0 0 1 F86 VIP Function Penthousefunction and priority for hall 0 priority for hall 0 VIP delay...
Страница 56: ...lose after command 0 F120 Number of registrations an nuisance Violation detection interior call 0 no function 1Stop without erasing light grid command 2 20max Number of accepted commands at the same t...
Страница 57: ...pens without keep close moment Bit 3 keep close during the journey in case tie bolt bangs against the locking bolt Bit 4 no door close end switch Bit 5 AT120 door control Bit 6 revolving door 0 0 7 F1...
Страница 58: ...ircuit detection 0 with add relay only for Asia 1 Standard only via high voltage inputs 1 0 1 F157 free F158 free F159 free F160 Cancel Call mode Cancel call permitted not permitted 1 0 1 F161 Block f...
Страница 59: ...pproved with RFID Bit mask Interior calls 33 48 0 65535 F173 free F174 free F175 Start creep speed Start creep speed 0 006m s 0 0 100 F176 free F177 free F178 free F179 free F180 Speed gain Assignment...
Страница 60: ...198 free F199 NS Etage 49 64 Blockable floor bitmask 49 64 0 65535 F200 SW Version Software Version of inverter x F201 Inverter Inverter modes 0 V F Mode 1 Vector Mode without encoder only test 2 torq...
Страница 61: ...RPM 80 00 0 00 655 35 F223 D3 Factor D Factor encoder at high RPM 0 50 0 00 655 35 F224 Freq 0 1 0 0 100 F225 Freq 1 50 0 0 100 F226 V0 Stoptime 0 5s 0 0 30 00 F227 Delay brake monitor Delay time for...
Страница 62: ...on exceeding nominal rotation speed 100 x0 01s 0 65535 F249 Confirmation times for inputting open phase Tolerance for case of missing phase on input 35 mal 0 65535 F250 Confirmation times of short cir...
Страница 63: ...v Negative rotation dead time Dead time for changing sense of rotation 20 x0 1s 20 60000 F254 Acceleration overcurrrent threshold of inverter The acceleration is limited if current exceeds the current...
Страница 64: ...low 20 of rated RPM x0 1 F252 Low speed overcurrent time Duration of Over current for low RPM x0 1s F253 Motor high speed overcurrent threshold Over current limit for RPM above 20 of rated RPM x0 1 F2...
Страница 65: ...r End switch up 2 defectous 13 Down Sw 2 Err End switch2 down defectous 14 Up Sw 3 Err End switch up 3 defectous 15 Down Sw 3 Err End switch 3 down defectous 16 Up Sw 4 Err End switch up 4 defectous 1...
Страница 66: ...X8 37 Dr Lock Error Only relevant for asia 38 Brake Sw Err Brake switch monitoring reports error Brake contactor active but brake is not activated brakes don t work synchronous X22 X23 39 Safety Rela...
Страница 67: ...ng doorzones doesn t match with number of stops 70 free 71 OC Protection Overcurrent protection 72 ADC Error Current sensor error Replace current sensor or mainboard 73 Radiator overheat 74 BK unit Er...
Страница 68: ...Err 95 Fan error 96 No encoder Teach 97 Output OC 98 SINCOS enc Err 99 Input phase lose 100 Overspeed Protct 101 Motor H speed OC 102 Ground Protection 103 Kcapacitance Agin 104 Outside Error 105 Outp...
Страница 69: ...4B 1A 2A 4A Code 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 Disp CF LB E A UB LG UG 6A 6B 7A 7B 5B 6C DG T OG Code 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158...
Страница 70: ...Manual overview of system 17 Parameters Motor types Seite 75...