Transformer 3 rated power
0 to 10000 kVA
1500 kVA
Number of redundant cells per phase
0 to 11
0
Bypass of the cell U1
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U2
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U3
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U4
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U5
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U6
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U7
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U8
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U9
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U10
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
Bypass of the cell U11
0 = Disable
1 = Mechanical bypass cell
2 = Manual activation of the bypass relay
3 = Automatic bypass after a manageable fault
4 = Automatic bypass by parallel association
0
MVW3000 | 1-28
Содержание MVW3000 Series
Страница 2: ......
Страница 58: ...1 QUICK REFERENCE OF PARAMETERS AND FAULTS MVW3000 1 52...
Страница 62: ...2 SAFETY INSTRUCTIONS MVW3000 2 4...
Страница 192: ...6 SPECIAL FUNCTIONS MVW3000 6 4...
Страница 262: ...7 DIAGNOSTICS AND TROUBLESHOOTING MVW3000 7 70...
Страница 263: ......