5
DETAILED PARAMETER DESCRIPTION
✓
NOTE!
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0410 - Motor magnetization current (Imr)
Adjustable range:
0.0 to 1024.0 A
Factory setting:
0.0 A
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
It is the value of the motor magnetization current.
✓
NOTE!
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0411 - Motor Flux Leakage Inductance
Adjustable range:
0.00 to 99.99 mH
Factory setting:
0.00 mH
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
It is the value of the motor flux leakage inductance.
✓
NOTE!
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0412 - Lr/Rr Constant
Adjustable range:
0.000 to 9.999 s
Factory setting:
0.000 s
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
It is the motor rotor time constant (Lr/Rr).
P0413 - Tm Time Constant
Adjustable range:
0.00 to 99.99 s
Factory setting:
0.00 s
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
It is the mechanical time constant.
✓
NOTE!
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
MVW3000 | 5-74
Содержание MVW3000 Series
Страница 2: ......
Страница 58: ...1 QUICK REFERENCE OF PARAMETERS AND FAULTS MVW3000 1 52...
Страница 62: ...2 SAFETY INSTRUCTIONS MVW3000 2 4...
Страница 192: ...6 SPECIAL FUNCTIONS MVW3000 6 4...
Страница 262: ...7 DIAGNOSTICS AND TROUBLESHOOTING MVW3000 7 70...
Страница 263: ......