5
DETAILED PARAMETER DESCRIPTION
P0446 - Base field current
Adjustable range:
0.1 to 999.9 A
Factory setting:
33.3 A
Acesso:
Menu
→
Configurations
→
Control
Description:
Current base used for the field current.
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0449 - Maximum field current (Brushless)
Adjustable range:
0.01 to 5.00 PU
Factory setting:
0.70 PU
Acesso:
Menu
→
Configurations
→
Protections
Description:
Maximum limit in PU of P0462 used in the control of the field current reference;
see Section 5.2 FIELD EXCI-
TATION SET (DC WITH BRUSHES) on page 5-3 of the User’s Manual
.
Set according to the possible overload on the inverter/exciter.
✓
NOTE!
This parameter is only visible on HMI when: P0950 = 1 (Synchronous motor with brushes) or
P0950 = 2 (Brushless synchronous motor).
P0450 - Minimum field current (Brushless)
Adjustable range:
0.01 to 5.00 PU
Factory setting:
0.01 PU
Acesso:
Menu
→
Configurations
→
Protections
Description:
Minimum limit in PU of P0462 used in the control of the field current reference,
see Section 5.2 FIELD EXCI-
TATION SET (DC WITH BRUSHES) on page 5-3 of the User’s Manual
.
Minimum field for frequency higher than P0452.
✓
NOTE!
This parameter is only visible on HMI when: P0950 = 1 (Synchronous motor with brushes) or
P0950 = 2 (Brushless synchronous motor).
P0451 - Minimum field for soft-start function
Adjustable range:
0.01 to 5.00 PU
Factory setting:
0.15 PU
Acesso:
Menu
→
Configurations
→
Protections
Description:
Minimum limit in PU of P0462 used in the control of the field current reference,
see Section 5.2 FIELD EXCI-
TATION SET (DC WITH BRUSHES) on page 5-3 of the User’s Manual
.
MVW3000 | 5-79
Содержание MVW3000 Series
Страница 2: ......
Страница 58: ...1 QUICK REFERENCE OF PARAMETERS AND FAULTS MVW3000 1 52...
Страница 62: ...2 SAFETY INSTRUCTIONS MVW3000 2 4...
Страница 192: ...6 SPECIAL FUNCTIONS MVW3000 6 4...
Страница 262: ...7 DIAGNOSTICS AND TROUBLESHOOTING MVW3000 7 70...
Страница 263: ......