5
DETAILED PARAMETER DESCRIPTION
P0260 - Analog output AO5 gain (unipolar isolated MVC4 board)
Adjustable range:
0.000 to 9.999
Factory setting:
1.000
Acesso:
Menu
→
Configurations
→
I/O
→
Analog outputs
Description:
It sets the gain of analog output AO4. For P0260 = 1.000 the output value of AO5 is set according to the
description “analog output indication scale” in P0262.
P0261 - AO6 Function
Adjustable range:
0 to 21
Factory setting:
5
Acesso:
Menu
→
Configurations
→
I/O
→
Analog outputs
Description:
For values in the factory default (P0261 = 5 and P0262 = 1.000) AO5 = 20 mA when Motor Current = 1.5 x P0295.
for further details related to the function of analog outputs.
P0262 - Analog output AO6 gain (unipolar isolated MVC4 board)
Adjustable range:
0.000 to 9.999
Factory setting:
1.000
Acesso:
Menu
→
Configurations
→
I/O
→
Analog outputs
Description:
It sets the gain of analog output AO6. For P0262 = 1.000 the output value of AO6 is set according to the
description “analog output indication scale” in P0262.
Table 5.43:
Analog output functions
Function
(AO1)
(AO2)
(AO3)
(AO4)
(AO5)
(AO6)
Full scale (10V)
Speed reference
0
0
0
0
0
0
1 x P0134
Total reference
1
1
1
1
1
1
1 x P0134
Actual speed
2
2
2
2
2
2
1 x P0134
Not used
3/4
3/4
3/4
3/4
3/4
3/4
Output current (with filter 0.5 s)
5
5
5
5
5
5
1,5 x P0295
PID process variable
6
6
6
6
6
6
1 x P0528
Active output current
7
7
7
7
7
7
Output power
8
8
8
8
8
8
3
PID reference
9
9
9
9
9
9
1 x P0528
Not used
10
10
10
10
10
10
Trace channel 1 to 8
11 a
18
11 a
18
11 a
18
11 a
18
11 a
18
11 a
18
The same as the one of
the chosen parameter
Inverter temperature
19
19
19
19
19
19
200 °C
PLC
20
20
20
20
20
20
Output voltage
21
21
21
21
21
21
1 x P0296
MVW3000 | 5-52
Содержание MVW3000 Series
Страница 2: ......
Страница 58: ...1 QUICK REFERENCE OF PARAMETERS AND FAULTS MVW3000 1 52...
Страница 62: ...2 SAFETY INSTRUCTIONS MVW3000 2 4...
Страница 192: ...6 SPECIAL FUNCTIONS MVW3000 6 4...
Страница 262: ...7 DIAGNOSTICS AND TROUBLESHOOTING MVW3000 7 70...
Страница 263: ......