2.
Rotate the DIAL to select any channel which has an “!” icon appended to the
channel number.
3.
Press the [MON/F] key, then press the [1(SCAN)] key to initiate Preferential
Memory Scanning. Only the channels which have an “!” icon appended to the
channel number will be scanned.
Programmable (Band Limit) Memory Scan (PMS)
Programmable (Band Limit) Memory Scan (PMS)
Programmable (Band Limit) Memory Scan (PMS)
Programmable (Band Limit) Memory Scan (PMS)
This feature allows you to set sub-band limits for either scanning or manual VFO
operation. For example, you might with to set up a limit (in North America) of 144.300
MHz to 148.000 MHz so as to prevent encroachment into the SSB/CW “Weak Signal”
portion of the band below 144.300 MHz. Here’s how to do this:
1.
Set the radio to the VFO mode by pressing the [V/M(WRITE MT)] key, if necessary.
2.
Using the techniques learned earlier, store (per the above example) 144.300 MHz
into Memory Channel #L1 (the “L” designates the Lower sub-band limit).
3.
Likewise, store 148.000 MHz into Memory Channel #U1 (the “U” designates the
Upper sub-band limit).
4.
Switch to the Memory mode by pressing the [V/M(WRITE MT)] key once, then
rotate the DIAL to select Memory Channel # L1.
5.
Press and hold the [V/M(WRITE MT)] key for 2 seconds to start the PMS; the “MR”
label will be replaced by “PMS” in the upper left-hand corner of the display.
6.
20 pairs of Band Limit memories, labeled L1/U1 through L20/U20 are available.
You therefore can set upper and lower operation limits on a number of bands, if you
like.
““““Priority Channel
Priority Channel
Priority Channel
Priority Channel”””” Scanning (Dual Watch)
Scanning (Dual Watch)
Scanning (Dual Watch)
Scanning (Dual Watch)
The VX-7R’s scanning features include a two-channel scanning capability which
allows you to operate on a VFO or Memory channel, while periodically checking user
defines Memory Channel for activity. If a station is received on Memory Channel which
is strong enough to open the Squelch, the scanner will pause on that station in
accordance with the Scan-Resume mode set via Menu Item (Scan Modes #3: RESUME).
See page xx.
Here is the procedure for activating Priority Channel Dual Watch operation:
1.
Recall the memory channel you wish to be the “Priority” operation.
2.
Press and hold the [MON/F] key for 2 seconds, then press the [BAND(BND DN)]
key. A “P” icon will appear to the right of the “MR” icon, indicating it is priority