KSTDV Series Gas Fireplace
CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE:
The combustible area above the facing must
not protrude more than 1/2" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
Figure 4 -
Ceiling and Side Wall Clearances
72”
(1829 mm)
Min.
Ceiling
12”
(305 mm)
Max. Depth
16”
(406 mm)
Min.
6”
(152 mm)
Min.
Hearth 8” Min.
(203 mm)
Noncombustible
Hearth Minimum
Fireplace Opening
Combustible Mantel
45°
1”
4”
5”
6”
”
3”
Figure 5 -
Mantel Clearance
Stud
Finish Wall
Combustible
Material Area
Top View
Follow these instructions carefully to
ensure safe installation. Failure to follow
in struc tions exactly can create a fi re hazard.
The appliance cannot be installed on a
carpet, tile or other combustible material
other than wood fl ooring. If installed on
carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or
noncombustible material panel ex tend ing
full width and depth of the appliance.
W
ARNING
16”
12”
10”
12”
6”
2
56O
”
Side View
Noncombustible
Material to Top of
Standoffs
CFM146d
Top of Fireplace
Opening
Never obstruct or modify the air inlet or
outlet grilles (louvers). This may create
a fi re hazard.
W
ARNING