26
20306743
KSTDV Series Gas Fireplace
OPTIONAL FAN BLOWER SYSTEM
NOTE
The black and white wires on the AC box
wiring harness are marked ‘Blower’, ‘Light’
and ‘Aux’. It is important to use the wires
marked ‘Blower’ or the control will not work
correctly.
W
ARNING
Electrical connections should only be
performed by a qualifi ed licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
Electrical Grounding Instructions: This
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
W
ARNING
BLOTKSTSC SIGNATURE COMMAND
BLOWER
The BLOTKSTSC Blower Kit requires the SCSACM A/C
Module and the TSFRSC remote to install and operate
this kit. Refer to blower instructions for installation and
remote instructions for operation.
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
{
{
Light
Optional
AUX
Blower (300w Max)
Figure 32 -
BLOTKSTSC Blower Wiring Diagram
Control Box
AC Module