4

20307393

5" x 8" DVP Termination Kit

Figure 4  Snapped

Assemble Slip Sections

The outer flue of the slip section should slide over the outer 

flue of the pipe section  and into (inner flue) the last pipe 

section (see Figure 5) .  

Slide together to the desired length, making sure that a 

1-1/2 in. outer flue overlap is maintained between the pipe 

section and slip section. 

The pipe and slip section need to be secured by driving 

two screws through the overlapping portions of the outer 

flues using the pilot holes (see Figure 6). 

This will secure the slip section to the desired length and 

prevent it from separating. The slip section can then be 

attached to the next pipe section.
If the slip section is too long, the inner and outer flues of 

the slip section can be cut to the desired length.

CORRECT

INCORRECT

Make sure the seams are not aligned to prevent unintention-

al disconnection.

Figure 5 Slip Section Pilot Holes

Figure 6  Screws into Slip Section

WARNING

Risk of Fire/Explosion! 

DO NOT

 break seals on slip 

sections. Use care when removing termination cap from 

slip pipe. If slip section seals are broken during removal 

of the termination cap, vent may leak.

WARNING

Fire Risk

Exhaust Fumes Risk

• 

Overlap pipe slip sections at least 1-1/2 inches.

• 

Use pilot holes for screws.

• 

Screws must not exceed 1 in. long.

• 

Pipe may separate if not properly joined.

Содержание KSTDV500(N/P)TSCSB

Страница 1: ... supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional ...

Страница 2: ...m 25 Optional Fan Blower Systems 26 BLOTKSTSC Signature Command Blower 26 Final Installation 27 Glass Frame Removal 27 Light Brick Installation 27 Rock Wool Placement 28 Log Placement 29 Safety Barrier Installation Instructions 31 Operating Instructions 32 Read Before Lighting 32 Operating Instructions 33 To Turn Off Gas 33 Signature Command System Operation Instructions 34 Features 34 Battery Ins...

Страница 3: ...ace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizzines...

Страница 4: ... Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TESTED TO ANSI Z21 88 2014 CSA 2 33 2014 STANDARDS A manufactured home USA only or mobile home OEM instal...

Страница 5: ...TIONS Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installations must be in accordance with the currentANSI Z223 1 NFPA 54 and or local codes having jurisdiction In Canada please consult provincial and or local author ities having jurisdiction for installations at el...

Страница 6: ...g Depth 36 914 mm 39 6 1007 mm 44 6M 1137 mm 456M 108 mm 4456O 1130 mm 38 6 981 mm 23 584 mm 24 610 mm 4956O 1257 mm 30 762 mm 25 635 mm 1156O 292 mm Figure 2 Fireplace and Framing Dimensions NOTE For exterior wall applications outdoor facing kit KST500SSDK is required In these installations the control side of the unit MUST face towards the interior of the building ...

Страница 7: ... FIREBOX FRAMING Firebox framing can be built before or after the appliance is set in place Construct firebox framing following Figure 2 for your specific installation requirements The framing headers may rest on the top of the firebox standoffs Do not bring headers below top of standoffs NOTE When planning your framing and installation keep in mind that your gas line will come in on the right sid...

Страница 8: ...install in the vicinity where gasoline or other flammable liquids may be stored Y D A B C E Y X Island C and Room Divider D installation is possible as long as the horizontal portion of the vent system X does not exceed 20 610cm See details in Venting Section When you install your fireplace in D Room divider or E Flat on wall corner positions Y a minimum of 6 152mm clearance must be maintained fro...

Страница 9: ...gure 5 Mantel Clearance Stud Finish Wall Combustible Material Area Top View Follow these instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fire hazard The appliance cannot be installed on a carpet tile or other combustible material other than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wood ...

Страница 10: ... surround are sealed a 300 F minimum sealant material General Electric RTV103 or equivalent must be used NOTE Never install combustible materials over front face of fireplace Figure 6 Secure Fireplace to Floor and Framing Studs Nailing Flange Screws Framing FP2545 Noncombustible Material SECURE FIREPLACE TO FLOOR OR FRAM ING The fireplace must be secured to the floor and or to framing studs as sho...

Страница 11: ...ommon vent systems WARNING Read all instructions completely and thoroughly before attempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious injury property damage or loss of life WARNING Failure to follow these instructions will void the warranty NOTICE 3 1 1 24 610...

Страница 12: ...pecially important in cold climates Insulation should be considered a combustible material Maintain proper clearances to all combustible materials WARNING Always maintain minimum clearances around vent systems The minimum clearances to combustibles for horizontal vent pipe are 3 at the top and 1 at the sides and bottom of the vent system until the pipe penetrates the nearest vertical wall 1 requir...

Страница 13: ...15cm for appliances 10 000 BTU h 3kW 9 23cm for appliances 10 000 BTU h 3kW and 50 000 BTU h 15kW 12 30cm for appliances 50 000 BTU h 15kW C Clearance to permanently closed window 12 305mm recommended to prevent window condensation 12 305mm recommended to prevent window condensation D Vertical clearance to ventilated soffit located above the terminal within a hor izontal distance of 2 610 mm from ...

Страница 14: ...r of the pipe on the fireplace Vertical Dimension From the Floor of Unit to the Center of the Horizontal Vent Pipe NOTE Termination in an alcove space spaces open only on one side and with an overhang is permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be a 3 914 mm min imum between termination caps 2 All mechanical air intakes within 10 1 m of a termi...

Страница 15: ...ired from the base of the flue collars to the center of the wall opening Figure 12 Step 4 Using appropriate length of pipe section s attach to fire place with three 3 screws Follow with the installation of the elbow Step 5 Measure the horizontal length requirement figuring a 11 4 32 mm overlap i e from the elbow to the outside wall cap Figure 13 X Figure 12 Vertical Height Requirement X Figure 13 ...

Страница 16: ... minimizes the number of offsets and horizontal vent length The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace or the top of the Transition Elbow to the face of the finished outside wall The maximum number of 90 elbows per side wall installation is three 3 Figure 14 Figure 14 Maximum Three 3 90 Elbows Per Installation 3 x 90 Elbows 24 Min FP1380 I...

Страница 17: ...el a snorkel kit is rec ommended It allows installation depth down to 7 178 mm below grade level The 7 178 mm is measured from the center of the horizontal vent pipe as it penetrates through the wall Ensure that sidewall venting clearances are observed If venting system is installed below ground we recom mend a window well with adequate and proper drainage to be installed around the termination ar...

Страница 18: ...2 feet or higher form floor of fireplace the clearance for the horizontal run is 1 on all sides Vertical sections of this vent system require a minimum of 1 clearance to combustibles on all sides of the pipe Up to two 45 elbows may be used within the horizontal run For each 45 elbow used on the horizontal plane the maximum horizontal length must be reduced by 18 457 mm B A 40 12 m Maximum Height 1...

Страница 19: ...space to combustibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations Offsets must fall within the parameters shown in Figures 24 and 25 2 Set fireplace in desired location Drop a line plumb down from the ceiling to the position of the fl...

Страница 20: ...ipe to combustible materials 6 Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements as shown in Figure 26 NOTE You must increase vent height for steep roof pitches Nearby trees adjoining roof lines steep pitched roofs and other similar factors may cause poor draft or down drafting in high winds Increasing the vent height may solve this problem...

Страница 21: ...test gauge connection Purchase the CSA design certified equip ment shutoff valve from your dealer For propane LP connections only the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regulator damage could occur Inst...

Страница 22: ...ed upstream of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed upstream of the appliance Figure 28 IMPORTANT Install main gas valve equipment shutoff valve in an accessible location The main gas valve is for turning on or shutting off the gas to the fireplace Check your building codes for any special requirements for locating equipment shutoff valve to firepl...

Страница 23: ...used for back up during power outages 2 The Signature Command System can also be operated without A C power The system can run on four 4 AA batteries for approximately six 6 months under normal use 3 A C power must be used to power the A C module blowers lights and AUX accessories used with this fireplace Optional Accessory Requirements 1 This fireplace may be used with a wall switch and or Signat...

Страница 24: ...t extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction box to lower control area at bottom of fireplace Unplug the 12 cable from the com mand center Attach the connector to the pins from wire by pushing in to connector making sure to follow the color code...

Страница 25: ...l Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve A C Module To Outlet Light 300 Watt Max Optional Blower 300 Watt Max Rear Burner Solenoid 300 Watt Max CHECKING GAS PRESSURE AND ELECTRICAL INSTALLATION CAUTION Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting fans to the main electrical power supply o...

Страница 26: ...ice Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle WARNING BLOTKSTSC SIGNATURE COMMAND BLOWER The BLOTKSTSC Blower Kit requires the SCSACM A C Module and the TSFRSC remote to install and operate this kit Refer to blower instructions...

Страница 27: ... right and left side of the glass toward the glass 4 Remove glass frame by releasing the three latches located at the top of the firebox Tilt glass away from the unit lift glass frame up and away from the unit Figure 33 CAUTION Each clamp has a quick spring force When reinstalling clamps keep fingers clear Figure 33 Remove Safety Barrier and Glass Frame DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOU...

Страница 28: ...ox Cover Figure 35 Remove Lens Retainer Bracket 3 The light bulbs are included in the Homeowner s Manual packet Install the light bulbs into bulb sockets as shown in Figure 34 CAUTION Finger prints or the transfer of oil from hands will reduce the lifespan of the bulbs It is advisable to handle the light bulbs with a clean cloth 4 The light lenses are included in the Homeowner s Manual packet Remo...

Страница 29: ...he notches in the log with the first tine from the right on both the front and the rear grates Log 3 3 Hold log 3 with the fat end to the right and the narrow end to your left Place the log over the key on the top of log 2 closest to you making sure to align the bump on the narrow end against the inside end of the second Figure 38 Figure 39 Figure 40 tine from the left Position log with the inside...

Страница 30: ... controls on your right and hold log 5 in your right hand with the knots at each end of the log facing you and the notched end on your left place the log on the key on the top of log 1 with the notch in the bottom of the log resting on the front of the third tine from the right Figure 42 8 Hold log 7 with the Y pointing away from you and place the log on the notch located on the top of log 3 angli...

Страница 31: ...to the shoulder bolts until it fits securely in place 4 Repeat on other side NOTICE It is the responsibility of the installer to ensure the barrier is affixed to the fireplace at the time of instal lation CERTIFIED SAFETY BARRIER NOTE A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and o...

Страница 32: ...as supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not function by hand do not try to repair it Call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately cal...

Страница 33: ... in the safety information on page 32 If you do not smell gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will light 6 Once pilot flame is established the main burner flame will light automatically 7 If the pilot will not stay lit after several tries tur...

Страница 34: ...n and off X BATTERY INSTALLATION The Command Center uses four 4 AA batteries as back up for power outages The system can operate for approximately six 6 months on battery power To Install Batteries not included 1 Press down the battery door tabs and pull out to remove battery door RF Receiver ON OFF NG LP Conversion To Thermopile To Sensor To Sparker To Command Center To Stepper Motor To Valve Bat...

Страница 35: ...if unattended You may disable this feature if you wish NOTE By disabling this feature your fireplace may con tinue to operate unattended 2 When the master switch is in the ON position pressing the ON button and the OFF button on the Command Center simultaneously will toggle between enabling and disabling the six hour shutdown option 3 After the above operation one beep for enabling the six hour sh...

Страница 36: ...then Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off The next time the fireplace is turned on all settings will resume To reset change to the desired settings and shut off by using the Memory Off commands and the system will be reset to those new settings COM...

Страница 37: ...er 1 All available icons on the LCD will be turned on then be cleared 2 The LCD will display temperature unit F Use ON to toggle the units between F and C within the first 5 seconds 3 The transmitter enters Manual Mode 4 The LCD displays room temperature with the chosen unit Function Areas of the LCD Display Figure 46 shows the display of the TSFRSC LCD Information Bar The information bar shows th...

Страница 38: ...vate the learn function for the trans mitter 3 After the above opera tion two beeps will be given and the green LED on the Command Center will flash for 10 seconds 4 During the 10 sec onds press the OFF button on the transmit ter to learn Another two beeps will be giv en to confirm success Figure 50 WARNING Do not use two 2 or more remote control sys tems in the same area with the same privacy cod...

Страница 39: ...hermostat Mode In both modes the fireplace will be shut down completely when the timer counts down to zero 6 To exit Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero Or c Slide down on the arrow buttons to exit TIMER mode and shut off the fireplace Thermostat Mode Figure 55 Press the THERMO button to set the transmitter in the...

Страница 40: ... mode The fan icon will start flashing 2 Press the ON up and OFF down button to increase decrease the blower speed 3 Press the fan button again to confirm the speed setting If the fireplace is on the blower speed will take effect right away if the fireplace is off the receiver will remember this setting and the blower is still off see blower On Delay and Off Delay in the next section 4 After the s...

Страница 41: ... seconds to toggle between A and B 1 When the current setting is A touch any place in the touch area to bring up the icons then press TIMER but ton and THERMO button at the same time for 3 sec onds The backlight will flash once to indicate that the setting has changed to B 2 When the current setting is B pressing TIMER button and THERMO button at the same time for 3 seconds will switch to A Mode T...

Страница 42: ...ver is more than 30 feet Make sure the transmitter has learned to the receiver Move transmitter to a cooler place and wait until temperature drops below 99 F Make sure the opening distance is less than 30 feet Blower is not on after the fireplace is turned on Blower setting is off Blower delay setting is set too high Press FAN key to select fan speed desired Press and hold FAN key to set desired O...

Страница 43: ... foreign material with a brush or vacuum BURNER FLAME The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation In normal operation at full rate and after operating for about 15 to 30 minutes the flame should be yellow and slightly taller than the rear log Figure 62 If the flame is blue and only in the center turn off unit and...

Страница 44: ...als may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposit on the inside of the glass should be cleaned off using a nontoxic non corrosive non abrasive mild cleaning solution Simply apply an adequate amount to the glass and wipe off with a damp cloth After...

Страница 45: ...upply Go through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check valve connections Check power supply go through A E Check grounding Go through B Go through C The sensor on the pilot is not in the flame pilot flame too small ACTION Re install batterie...

Страница 46: ...3D0020 2 Bulb Socket 2 73D4521 3 Glass Frame Assembly 2 73D0159 4 Junction Box Assembly not shown 1 26D2128 5 Light Lens 2 73D4057K 6 Access Doors 4 73D3258 7 Front Cover 2 73D4524 8 Screens 4 73D0017 9 Screen Rod 2 73D0010 10 Safety Barrier 2 20306577K 1 2 3 5 7 6 8 9 10 FIREBOX COMPONENTS AND ACCESSORIES ...

Страница 47: ...20306743 47 KSTDV Series Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM COMPONENTS 2 22 29 30 17 13 17 12 13 18 16 15 3 1 5 14 11 4 23 24 25 26 26 27 27 28 ...

Страница 48: ...Assy Front 2 1 73D4529 73D4529 17 Venturi Front Burner 2 73D4537 73D4537 18 Venturi Middle Burner 1 73D4537 69D1026 19 Wire Valve Control not shown 1 80D0010 80D0010 20 Wire AC Module not shown 1 80D0009 80D0009 21 Wire Command Ctr not shown 1 80D0008 80D0008 22 Remote Transmitter full function 1 TSFRSC TSFRSC 23 Solenoid 1 20301204 20301204 24 Flex Line Manifold 1 20H0022 20H0022 25 Tube Solonoid...

Страница 49: ... Series Gas Fireplace REPLACEMENT PARTS Item Description Qty KSTDV500 1 Log 1 1 73D4090 2 Log 2 1 73D4091 3 Log 3 1 73D4092 4 Log 4 1 73D4093 5 Log 5 1 73D4094 6 Log 6 1 73D4095 7 Log 7 1 73D4096 8 Log 8 1 73D4097 LOGS ...

Страница 50: ...Eng Side 1 73D4127 73D4132 73D4149 2 Brick Wall Air Side 1 73D4128 73D4133 73D4150 3 Brick Floor 2 73D4129 73D4134 73D4151 4 Brick Front Left 2 73D4130 73D4135 73D4152 5 Brick Front Right 2 73D4131 73D4136 73D4153 Herringbone Pattern 6 Brick Wall Eng Side 1 73D4137 73D4143 7 Brick Wall Air Side 1 73D4138 73D4144 8 Brick Floor 2 73D4139 73D4145 9 Brick Front Left 2 73D4140 73D4146 10 Brick Front Ri...

Страница 51: ...20306743 51 KSTDV Series Gas Fireplace HOT 1 2 3 4 5 6 9 7 8 10 VENT COMPONENTS REPLACEMENT PARTS For models purchased after 4 16 15 please see addendum ...

Страница 52: ...ilt In Vinyl Siding Standoff BHSF58TK Heat Deflector Firestop Flexible Pipe 20 to 48 Adapter 1 8 Horizontal Termination w 1 Firestop BHR58T 8 1 1 Horizontal High Wind Termination Cap 58DVA HC 1285 5DT HC 1 1 Horizontal Termination Cap 5DHT 2 1 Vertical Termination see below see below 5DT VC 5DVT 2 1 Extended Vertical Termination 58DVA VCE 1283 2 1 High Wind Vertical Termination 58DVA VCH 1291 3 4 ...

Страница 53: ...20306743 53 KSTDV Series Gas Fireplace ...

Страница 54: ...to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ONLY 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 Signage ...

Страница 55: ... Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation ...

Страница 56: ...V Series Gas Fireplace EFFICIENCY RATINGS Model EnerGuide Ratings Fireplace Efficiency D O E AFUE KSTDV500NTSC 77 30 67 40 KSTDV500PTSC 74 30 66 35 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com ...

Страница 57: ...Standards and will operate safely when installed in accordance with this instruction manual Read all instructions before starting installation then follow these instructions carefully to maximize fireplace performance and safety Report damaged parts to your dealer WARNING Always maintain minimum clearances around vent systems Rear Top Vent Vertical Side wall Horizontal sections of this vent system...

Страница 58: ...initial use and at least annually by a qualified field service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow Inspect entire venting system to en sure proper function Figure 1 Termination Cap on Wall Outside Wall Finishing Material Vinyl Siding etc PRE INSTALLATION INFORMATION Before You Start Plan your installation Set the unit ...

Страница 59: ...k to make sure they have snapped together see Figure 3 and the seams are not aligned see Figure 4 Tug slightly on section A to confirm it has completely locked into place It is acceptable to use screws no longer than 1 in to hold outer pipes together If predrilling screw holes do NOT penetrate inner pipe For 90 and 45 elbows that are changing the vent direction from horizontal to vertical one scre...

Страница 60: ...ength and prevent it from separating The slip section can then be attached to the next pipe section If the slip section is too long the inner and outer flues of the slip section can be cut to the desired length CORRECT INCORRECT Make sure the seams are not aligned to prevent unintention al disconnection Figure 5 Slip Section Pilot Holes Figure 6 Screws into Slip Section WARNING Risk of Fire Explos...

Страница 61: ...ical Pipe Sections Figure 8 Securing Horizontal Pipe Sections Figure 10 Align and Disassemble Vent Sections Figure 9 Rotate Seams for Disassembly INSTALL HORIZONTAL TERMINATION CAP Note For horizontal vent runs through a combustible wall and framing dimensions refer to appliance installation manual WARNING Risk of Fire Explosion Asphyxiation Improper support may allow vent to sag and separate Use ...

Страница 62: ...ap base Flash and seal as appropriate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current ANSI Z223 1 and CAN CGA B149 installation codes Divert Roof Run off VCG HHT recommends where excessive water run off is possible use of one of the two options shown below to prevent water running off the roof and ...

Страница 63: ...therwise adjust pipe to desired length 4 A wall square firestop MUST BE installed if the vent passes through a ceiling or exterior combustible wall Cut a 10 wide x 10 high 254 x 254 mm opening through the wall or framing A wall rectangular firestop MUST BE installed if the vent passes through interi or walls In that case cut a 10 wide x 12 high 254 x 305 mm opening through the wall or framing The ...

Страница 64: ...me time slide the outer flue over the outer collar of the appliance Push the flex starter section into the appliance collar until all the lances have snapped in place Tug slight ly on the section to confirm it has completely locked into place Install three 3 self tapping 10 screws through the DVP flex starter into the starting collar of the appliance 5 Slide one end of the 5 flex pipe over the inn...

Страница 65: ...high 254 x 305 mm opening through the wall or fram ing The framing members may need to be reinforced Position the firestop on the hole previously cut and se cure with screws or nails not provided Run vent pipe through firestop The gap between the vent pipe and firestop may be sealed 2 Attach slip section of cap to last vent section Maintain 11 2 in overlap between slip and vent sections Make sure ...

Страница 66: ...stall three 3 self tapping 10 screws through the DVP flex starter into the starting collar of the appliance 2 Slide the small gear clamp over the inner flexible vent pipe and push out of the way 3 Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter collar for a minimum 2 overlap 5 Locate the clamp at approximately 3 4 from the flex end and tighten 6 Secure the clamped i...

Страница 67: ...igure 19 Secure with three fasteners on each side Do not pack insulation around the pipe Insulation must be kept away from the pipe The gap between the vent pipe and firestop may be sealed Figure 18 Installing Ceiling Firestop 3 fasteners per side Ceiling firestop installed below ceiling Ceiling firestop installed above ceiling Install attic insula tion shields before or after installation of vent...

Страница 68: ...d outward on the bottom of the shield to allow attachment to ceiling firestop Bend remaining tabs inward on bottom of shield where it rests on the ceiling firestop to maintain the air space between the pipe and shield Set the shield on the ceiling firestop Bend all tabs inward 90 around the top of the shield These tabs must be used to prevent blow in insulation from getting between the shield and ...

Страница 69: ...of to Lowest Discharge Opening Caulk the gap between the roof flashing and the outside diameter of the pipe Caulk the perimeter of the flashing where it contacts the roof surface Caulk Pipe Flashing Figure 24Caulk the Gap Install Roof Flashing To install roof flashing see Figures 24 and 25 For installation of vertical termination cap see minimum vent heights for various pitched roofs see Figure 23...

Страница 70: ...r dimples in the outer collar of the cap into the outer flue of the vent See Figure 26 Termination Cap 1 of 3 Storm Collar Screws Caulk Figure 26Secure with Screws Attaching Flexible Venting to Vertical Termination Kit 1 Attach the inner flex adapter to the inner pipe of the rig id pipe length using three 3 self tapping 10 screws 2 Attach the outer flex adapter to the outer pipe of the rigid pipe ...

Страница 71: ...ter UL1777 Flex Pipe Flex Adapter Starter Roof Support Refer to Figures 5 6 Firestop Secure Screws 3 Places Equidistant Just Above Gear Clamp Gear Clamp 2 Flexible Pipe and Adapter Outer Collar Overlap Rigid Pipe Length Flex Adapter Outer Figure 28 Typical Vertical Termination Connection UL1777 Flex Vent Flex Adapter Inner Flex Adapter Outer Flex Adapter Inner ...

Страница 72: ...149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com ...

Отзывы: