EUROBLOC
SERVICE MANUAL FOR HOIST
174/212
This document and the information contained herein, is the exclusive property of Verlinde S.A.S. and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Verlinde S.A.S.
Copyright © (2013) Verlinde S.A.S. All rights reserved.
06/2015
Reassembly
1
2
Assemble the set of plate springs (3) and secure in place
with screws.
Loosen the screw (5) and install the limit switch (4). Adjust
the screw (5) so that its end lies 2…3 mm above the limit
switch trigger.
3
4
Place the sleeve (7) on the ends of the overload device and
insert the assembly into position. Secure the overload device
into place with washer and screws (6).
Install the machinery covers. Switch ON the power supply to
the hoist.
Overload protection, load sensor
1. Rope anchorage
2. Lever mechanism
3. Load sensor
4. Safety limit switch