EUROBLOC
SERVICE MANUAL FOR HOIST
127/212
This document and the information contained herein, is the exclusive property of Verlinde S.A.S. and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Verlinde S.A.S.
Copyright © (2013) Verlinde S.A.S. All rights reserved.
06/2015
3
4
All: Raise the hook until it is minimum 100 mm below the
specified C-dimension, or minimum 100 mm under any fixed
steel structure.
All: Turn the screw “S3” until the limit switch “S3” is just
activated.
All: Test the operation. The upward motion must slow down to
Low speed at the described distance.
5
6
All: Raise the hook until it is at the specified C-dimension, or
minimum 50 mm under any fixed steel structure.
All: Turn the screw “S2” until the limit switch “S2” is just
activated.
All: Test the operation. The upward motion must stop at the
described distance.
7
8
c_holiad1b
All: Raise the hook to the upmost position, until the motion is
stopped by the upper limit switch “S2”.
All: Turn the screw “S1” so that it will activate just after “S2” (in
upwards direction).
Black model: Tighten the locking screw (5)
All: Close the connection box cover.