The results are sent to a separate TDWR/LLWAS Integrator. The Integrator takes data from
LLWAS (if available) and configuration information on the current active runways from the
runway utility. The output back to IRIS is a TDWR product that is filtered so that only the
information required by the ribbon display is present. The integration algorithm is the
FAA/MIT Lincoln Lab algorithm that was developed for the U.S. FAA TDWR.
Usually both IRIS and the Integrator run on the RPG, although it is possible to run the
TDWR/LLWAS Integrator on an SD. This would, however, lead to configuration chaos since
there are likely to be many SD's.
The RPG then outputs the TDWR product to the SD's and when it is received, it is
automatically formatted into a ribbon display message and sent out the SD serial line.
The process that outputs the products to the RBDT's has an additional configurable filter:
The controller can specify which corridors are displayed on an SD. Use the
ribsetup
to
configure this.
D.5 IRIS/TDWR Configuration Summary
You must install and configure the TDWR components by performing the following
procedures.
1. Configure IRIS for TDWR operation.
a. Configure the runway arenas (protected areas).
See
Configuring Protected Areas (Arenas) for TDWR (page 338)
.
b. Configure the scan tasks and the
SLINE
and
SHEAR
products.
See
Configuring IRIS Tasks and Products for TDWR (page 340)
.
c. Configure the outputs to the Integrator and the SD's.
See
Configuring IRIS Product Outputs for TDWR (page 340)
.
2. Install and configure the Ribbon Displays. See:
•
•
Configuring Ribbon Display Software (page 347)
3. Configure the TDWR/LLWAS Integrator (
runways.conf
).
See
TDWR/LLWAS Integrator and Runways Utility (page 353)
.
4. Use the
runways
utility to set the runway direction.
See
D.6 IRIS Preparation
Preparing the IRIS system involves setting-up the protected areas, scan strategy, product
generation, and output for TDWR operation.
D.6.1 Configuring Protected Areas (Arenas) for TDWR
Protected areas are configured in the IRIS
Setup > Product
utility.
IRIS Product and Display User Guide
M211319EN-H
338
RESTRICTED
Содержание IRIS
Страница 1: ...M211319EN H RESTRICTED User Guide IRIS Radar IRIS Product and Display...
Страница 12: ...IRIS Product and Display User Guide M211319EN H 10 RESTRICTED...
Страница 71: ...Chapter 3 Configuring IRIS Products RESTRICTED 69...
Страница 294: ...To add icons you must include a text next to the icon IRIS Product and Display User Guide M211319EN H 292 RESTRICTED...
Страница 303: ...Figure 103 Typical Spectrum Plot Appendix A Basic Radar Meteorology RESTRICTED 301...
Страница 324: ...Figure 109 Example of Volume Rendering IRIS Product and Display User Guide M211319EN H 322 RESTRICTED...
Страница 329: ...C 8 Using the Product Information Tool Figure 113 Product Information Tool Appendix C IRIS 3DView RESTRICTED 327...
Страница 386: ......
Страница 392: ......
Страница 393: ......
Страница 394: ...www vaisala com...