S e c t i o n 5 : P r o g r a m m i n g
34
• Bell Squawk on Exit (single every second)
• Bell Squawk on Entry (single every second)
• Bell Squawk on Trouble (single every 10 seconds)
OFF: Squawks do not activate the main siren.
[001]-[164] PGM 1-28 Attributes
The following PGM attributes can be assigned to a PGM. Each attri-
bute has various toggle options, depending on the PGM type selected
(section [009]).
101 – Fire and Burglary
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
102 – Delay Fire and Burglary
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
103 – Sensor Reset [*][7][2]
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
03 – Access Code Required / No Code Required
ON – Access code required for activation
OFF – No access code required for activation
109 – Courtesy Pulse
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
111 – Keypad Buzzer Follow
01 – True Output/Inverted
ON: deactivated during normal operation, activated when
triggered.
OFF: activated during normal operation, deactivated when
triggered.
02 – Timed Output / Latched Output
ON: output remains active until an access code is entered or cer-
tain criteria have been met, depending on the PGM type.
OFF: output remains active until the PGM output timer expires.
09 – Entry Delay
ON: activates on entry delay.
OFF: does not activate on entry.
10 – Exit Delay
ON: activates on exit delay.
OFF: does not activate on exit delay.
11 – Door Chime
ON: activates when chime is enabled.
OFF: does not activate when chime is enabled.
12 – Keypad Buzzer Zone
ON: activates when keypad buzzer goes into alarm.
OFF: does not activate when keypad buzzer goes into alarm.
13 – Audible Exit Fault
ON: activates when audible exit fault pre-alert begins.
OFF: does not activate when audible exit fault pre-alert begins.
14 – Auto-Arm Pre-Alert
ON: activates when auto-arming pre-alert begins.
OFF: does not activate when auto-arming pre-alert begins.
114 – Ready To Arm
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
115 – Armed Status
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
116 – Armed Away Mode
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
117 – Armed Stay Mode
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
121-124 – Command Output 1-4
01 – True Output/Inverted
ON: deactivated during normal operation, activated when
triggered.
OFF: activated during normal operation, deactivated when
triggered.
02 – Timed Output / Latched Output
ON: output remains active until an access code is entered or
certain criteria have been met, depending on the PGM type.
OFF: output remains active until the PGM output timer expires.
03 - Access Code Required / No Code Required
ON – Access Code Required for Activation
OFF – No Access Code Required for Activation
129 – Partition Status Alarm Memory
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
132 – Holdup Output
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
146 – TLM Alarm
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
147 – Kissoff Output
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
148 – Ground Start
01 – True output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
149 – Alternate Communicator
01 – True Output/Inverted
ON: deactivated during normal operation, activated when
triggered.
OFF: activated during normal operation, deactivated when
triggered.
02 – Timed Output / Latched Output
ON: output remains active until an access code is entered or cer-
tain criteria have been met, depending on the PGM type.
OFF: output remains active until the PGM output timer expires.
04 – Fire Alarm