4.0.2 SIA False Alarm Reduction Installations: Quick Reference
Minimum required system consists of one Control unit model HS2128 or HS2064 or HS2032 or HS2016 and any one of the compatible listed keypads: HS2LCDRF9, HS2LC-
DRFP9, HS2ICNRF9, HS2ICNRFP9, HS2LCD, HS2LCDP, HS2ICN, HS2ICNP, HS2LED.
The following wireless keys can also be used in SIA compatible installations: PG9929, PG9939,PG9949.
NOTE:
For models PG9929 and PG9939, the panic/emergency key shall be disabled for SIA compliant installations.
For a list of the default values programmed when the unit is shipped from the factory, and for any other programming information, refer to the table below.
The following optional subassembly modules also bear the SIA CP-01-2010 classification and may be used if desired: HSM2108 zone expander, HSM2208 PGM output module,
HSM2300 auxiliary power supply, HSM2204 output module, HSM2HOST9 2-way wireless transceiver, PG9901 indoor siren, PG9911 outdoor siren, and 3G2080(R)/ TL2803G(R)/
TL280(R) cellular and PSDN communication module.
Caution
•
For SIA FAR installations use only modules/devices that are listed on this page.
•
Fire Alarm Verification feature (Auto Verified Fire Zone type [025]) is not supported on 2-wire smoke detectors zones, model FSA-
210B(T)(S)(ST)(LST)(R)(RT)(RD)(RST)(LRST). This feature may be enabled for 4-wire smoke detectors only (FSA-410B(T)(S)(ST)(LST)(R)(RT)(RST)(LRST) and wire-
less detectors PG9916/PG9926). The fire alarm delay is 60s.
•
Call Waiting Cancel (Section [382], Option 4) feature on a non-Call Waiting line will prevent successful communication to the supervising station.
•
All smoke detectors on the system must be tested annually by conducting the Installer Walk Test. Prior to exiting walk test mode, a sensor reset must be done on the system,
[*][7][2], to reset all latching 4-wire smoke detectors. Refer to the installation instructions supplied with the detector for details.
Notes
•
Programming at installation may be subordinate to other UL requirements for the intended application.
•
Cross zones have the ability to individually protect the intended area (e.g. motion detectors which overlap).
•
Cross zoning is not recommended for line security Installations nor is it to be implemented on exit/entry zones.
•
This control panel has a communication delay of 30 seconds. It can be removed or increased up to 45 seconds by the end user in consultation with the installer.
•
The security system shall be installed with the sounding device activated and the communicator enabled for transmission using SIA or CID format.
•
ULC commercial burglary installations require DEOL resistors.
SIA Feature Programming Section
Comments
Range/Default
Requirement
Exit Time
[005]>[001], option 3
Access to Entry and Exit delays and Bell Time Out for the system.
Range
:
45- 255 seconds
Default:
60 sec.
Required
(programmable)
Progress Annunciation/Disable - for Silent Exit
[014], option 6 ON
Enables audible exit beeps from the keypad for the duration of exit delay. Individual keypads may be disabled
Default:
Enabled
Allowed
Exit Delay Restart
[018], option 7
Opening a Delay zone door after it has already been opened and closed
during an exit delay restarts the exit delay timer.
Default:
Enabled
Required
Auto Stay Arm on Un-vacated Premises
[001]>[001]-[128] Zone type 05, 06,09
Function key: Forces the system to arm in Stay mode if the occupant does
not exit the premises after pressing the Away function key.
If no exit after full arm
Default:
Enabled
Required
Exit Time and Progress Annunciation/Disable
or Remote Arming
[861]>[001]-[005], option 4
System times and audible exit beeps can be disabled when using the wire-
less key to stay arm the system. When away arming, audible exit beeps
can not be disabled.
Default:
Enabled
Allowed
Entry delay(s)
[005]>[001]-[008], options 1 and 2
Access to entry and exit delays and bell time out for the system
Note:
Combined entry delay and communications delay (abort window)
shall not exceed 60s.
Range:
30 sec. to 4 min.
Default:
30 sec.
Required
(programmable)
Abort Window for Non-Fire zones
[002]>[001]-[128], option 7 ON
Access to zone attributes, i.e., swinger shutdown, transmission delay and
cross zone. May be disabled by zone or zone type.
Default:
Enabled
Required
Abort Window Time - for Non-Fire zones
[377]>[002], option 1
Access to the programmable delay before communicating alarms
Note:
Combined entry delay and communications delay (abort window)
shall not exceed 60 seconds.
Range:
00 - 45 sec.
Default:
30 sees
Required
(programmable)
Abort Annunciation
An audible tone is generated when an alarm is aborted during the abort
window.
Hard-coded ON
Required
Duress Feature
[*][5]> master code> user 2-95> 5> 2
When this feature is enabled, selected user codes send a duress reporting
code to the central station when used to perform any function on the sys-
tem. Section [019], option [6] must be enabled.
Default:
N
Required
Cancel Window
[377]>[002], option 6
Access to the communications cancel window. Minimum duration must
be 5 minutes.
Range:
005-255
Default:
005
Cancel Annunciation
[308]>[001], option 8
Access to the reporting code for Alarm Canceled.
A Cancel was transmitted
Default:
Enabled
Required
Cross Zoning
[042]>Selection 3, option 002
Enables cross zoning for entire system. Zones can be enabled for cross zon-
ing via zone attribute option 8 in sections [002][101] - [128].
Programming required
Default:
Disabled
Required
Burglary Verification Timer
[005]>[000], option 3
Access to the programmable Cross Zone timer.
Range:
000-255 sec.
Default:
60 seconds
Allowed
Swinger Shutdown for Alarms
[377]>[001], option 1
Access to the swinger shutdown limit for zone alarms
For all non-fire zones, shut down at 1 to 6 trips.
Default:
2 trips
Required
(programmable)
Swinger Shutdown Enable
[002]>[001] - [128], option 6 ON
Access to swinger shutdown, transmission delay and cross zone attributes.
Zone attribute option 6 (Swinger Shutdown enabled) is ON.
Non-police response zones
Default:
Enabled
Allowed
24-Hr. Auto-verified Fire
[001]>[001]-[128], Zone type 025 ON
Access to 24-Hr. Auto-verified Fire
Activates if Not restored within the specified time.
Must choose zone type for application Required
Call Waiting Cancel
[382], option 4 OFF
Access to the dialing sequence used to disable call waiting. Call waiting
string can be programmed in [034]
Depends on user phone line
Default:
Disabled
Required
System Test:
[*][6] Master Code, option 4
The system activates all keypad sounders, bells or sirens for 2 seconds
and all keypad lights turn on. Refer to user manual
(part no. 29008365).
Walk Test Mode:
[*][8][Installer code][901]
This mode is used to test each zone on the system for proper functionality.
Walk Test Communications
[382], option 2
Enables communication of zone alarms while walk test is active.
Default:
Disabled
Walk Test Start/ End Reporting Codes
[308][401], options 1 and 2
Access to the reporting codes for walk test start and end times.