S e c t i o n 5 : P r o g r a m m i n g
39
3 – Keypad Blanking
ON: If no keys are pressed for 30 seconds, all keypad lights except
backlighting (if enabled) are shut off until the next keypress, entry
delay, audible alarm or keypad buzzer condition.
Keypad function keys still operate when the keypad is blank, unless
the function key is programmed to require an access code. Keypad
Blanking While Armed overrides this feature. When a partition is
armed and in alarm, entering a code to remove blanking silences the
alarm and disarms the system.
OFF: The keypad lights remain ON at all times.
4 – Keypad Blanking Requires Code
ON: A valid access code must be entered before a blanked keypad
can be used.
OFF: Pressing any key on a blanked keypad removes keypad blank-
ing.
5 – Keypad Backlighting
ON: All keypads on the system have backlighting on at all times.
OFF:
All keypads on the system have backlighting off.
6 – Power Save Mode
ON: If AC power fails, all keypad lights including backlighting are
shut OFF. The keypad lights come back ON after a keypress, entry
delay, audible alarm or keypad buzzer condition (except door chime).
Keypad lights return to the off state after 30 seconds of inactivity.
OFF: If AC power fails, keypads do not go into power save mode.
7 – Bypass Display When Armed
ON: The Bypass status light is on if zones are bypassed when the sys-
tem is armed.
OFF: The Bypass light is on only while the system is disarmed to
indicate that zones on the system are bypassed. When the system is
armed, the Bypass light is off.
The Bypass status light is on if Stay/Away zones are auto bypassed at
the time of arming regardless of whether or not this option is enabled.
This option only enables and disables manual bypass display.
8 – Keypad Tampers Enabled
ON: All keypads containing tamper switches generate tamper alarms
and restores.
OFF: The tamper switches on all keypads do not generate tamper
alarms.
NOTE:
If this option is used, all keypads should be properly
installed and secured (tamper restored) before enabling the option.
NOTE:
Must be ON for UL/ULC commercial burglary listed instal-
lations.
[017] System Option 5
1 – Chime on Opening
ON: When a zone with the door chime attribute ON is opened, the
system keypads and sirens (if enabled) sound door chime beeps.
OFF: When a zone with the door chime attribute ON is opened, the
system keypads and sirens (if enabled) do not sound door chime
beeps.
2 – Chime on Closing
ON: When a zone with the door chime attribute ON is closed, the
system keypads and sirens (if enabled) sound door chime beeps.
OFF: When a zone with the door chime attribute ON is closed, the
system keypads and sirens (if enabled) do not sound door chime
beeps.
4 – Multi Hit
ON: Alarms from the same zone within the Burglary Verification
Timer duration cause the police code or burglary verified to be
logged and transmitted. The number of zone trips required to create a
confirmed alarm depends on the value of the programmable burglary
verification counter.
OFF: Alarms from the same zone within the Burglary Verification
Timer duration do not cause the police code or burglary verified to be
logged and transmitted.
NOTE:
This feature only applies to zones defined as Interior, Inte-
rior Delay, Interior Stay/Away, Instant Stay/Away, Delay Stay/Away,
or Night Zones (PIR Zones).
5 – Late to Close
ON: Provides an audible warning if the alarm system has not been
armed by a programmed time of day but does not arm the alarm sys-
tem. The alarm system communicates and logs a Late to Close event
at the end of the Auto-arm/Postpone pre-alert for each partition.
OFF:
The alarm system will neither communicate nor log a Late to
Close event at the time programmed for Auto-arm for each partition.
NOTE:
If the Auto-arm toggle option is disabled, the Auto-arm Pre-
alert still occurs when a time is programmed for that day (if enabled)
and the event is logged and communicated. This option does not
directly affect the functionality of Auto-arm. If Late to Close is
enabled and Auto-arming is not, LCD keypads display “System
Arming in Progress” during the Late to Close Pre-alert.
6 – Daylight Savings Time
ON: The alarm system adjusts between Daylight and Standard times
according to the times programmed in System Timers ([005] options
001-002).
NOTE:
Auto-arm and Test Transmissions should not be attempted
between 0200 and 0300 hours, as they will be missed during a day-
light savings clock adjust. Events programmed to occur between
0100 and 0200 will occur twice during a daylight savings clock
adjust. Daylight Savings Time programming should not conflict with
the Auto-arm and Test Transmissions programming.
OFF: The alarm system makes no automatic time adjustments for
Daylight Saving time.
7 – Not Used
8 – Bell Squawk on Away Arm/ Disarm Only
ON: Bell Squawks are only heard when away arming, as well as
when disarming from Away mode. This feature prevents the siren
from activating when arming in stay and night modes.
OFF: Bell Squawks are heard during all types of arming and disarm-
ing.
NOTE:
This option follows the “Bell Squawk Attribute” features if
they are enabled.
[018] System Option 6
1 – Test Transmission Exception
ON: The alarm system does not send a test transmission if a transmis-
sion was sent to the receiver within the programmed interval as set in
section [377] > [003] – Periodic Test Transmission Cycle on page 48.
OFF: Test transmissions are always sent at the programmed interval.
2 – Real-Time Bypass Reporting
ON: When a non-24-hour zone is bypassed in [*][1], the system
immediately logs and communicates the bypass status of the zone.
Global Zones: 24-hour and non-24 hour zone bypasses are logged
and communicated in real time. Non-24 hour zone unbypass events
are generated when the last assigned partition is disarmed.
OFF: When a non 24-hour zone is bypassed in [*][1], the system logs
and communicates the bypass status of the zone only after the parti-
tion is armed. This option is applied regardless of how zones are
bypassed in [*][1], recall bypass group, clear all bypasses, bypass