119
Appendix G: Specifications
Zone Configuration
•
16, 32, 64, or 128 wireless zones supported and 8 hardwired zones
available on the controller
•
40 zone types and 14 programmable zone attributes
•
Zone configurations available: normally closed, single EOL and DEOL
supervised
•
Hardwired zone expansion (fully supervised) available using the model
HSM2108 (eight zone expander module)
•
Wireless zone expansion (fully supervised) available using the
HSM2Host 2-way wireless integration module (operating at 915MHz
(North America), 433MHz (Europe) and 868MHz (international)
Access Codes
•
Up to 97 access codes: 94 (level 2-EN), one system master code (level
3-EN), one installer code (level 3-EN), and one maintenance code
•
Programmable attributes for each user code (see page 20)
•
When using 6-digit access codes, the minimum number of variations of
access codes are 10526 for HS2128/HS2064,13888 for HS2032 and
20833 for HS2016
Warning Device Output
•
Integral sounder capable of 85 dB @ 3m, self-powered type Z
•
2 remote, wireless indoor/outdoor warning devices supported: models
PGX901 (indoor), PGX911 (outdoor) (X=4, 8, or 9)
•
Programmable as steady, pulsed or temporal three (as per ISO8201)
and temporal four (CO alarm) output
•
Warning device sounds alarms in the following priority: fire, CO, med-
ical, burg
Memory
•
CMOS EEPROM memory
•
Retains programming and system status on AC or battery failure for 20
years min. (not verified by UL)
Power Supply
Transformer: DSC PTD1640U
Primary:120V, 60Hz Class II
Secondary:16.5VAC, 40VA Max.
Regulated power supply:
• 700mA auxiliary supply, 12V DC
• Positive temperature coefficient (PTC) for Bell, Aux+ and
Battery terminals
• Reverse battery detection/protection
• Supervision for AC power and low battery
• Normal and high current battery charge options
• Supervised battery charging circuit
Current draw (panel): 85mA (nominal) 2A(Max)
Bell Output:
• 12V, 700mA supervised (1k Ohm) bell output (current lim-
ited at 2 amps)
• Steady, Pulsed, Temporal 3 fire, CO alarm cadences
• Bell short detection (so hardware)
Aux+:
• Voltage range = 9.6V - 13.8V DC
• Current = 700mA (shared with PGM outputs)
•
Output ripple voltage: 270mVp-p max.
•
Onboard programmable outputs:
• PGM 1 - 50mA switched programmable output
• PGM 2 - 300mA current-limited switched programmable out-
put. 2-Wire smoke detectors (90mA current limited) are sup-
ported using this PGM
• PGM 3 - 50mA switched programmable output
• PGM 4 - 50mA switched programmable output
• Hardware PGM over current protection
Battery
•
12V sealed lead acid, rechargeable
•
Battery capacity:
• 4Ah (PS4-12)
• 7Ah (BD7-12)
• 14Ah
•
Maximum standby time: 24 hours (with 14Ah battery and Aux current
limited to 470mA)
•
Recharging time to 80% 72 hours
•
Recharging rate: 240mA (12 hours max.), 480mA (24 hour backup)
•
Backup time: 24 hours (UL)
•
Battery lifespan: 3-5 years
•
Low battery trouble indication threshold 11.5VDC
•
Battery restore voltage 12.5V
•
Main board current draw (battery only):
• HS2016/32/64/128 (no alternate communicator) standby
80mA DC
• HS2016/32/64/128, (including alternate communicator)
standby190mA DC
• Transmit (alternate communicator module)195mA DC
•
Resettable fuses (PTC) used on circuit board
•
Supervision for loss of primary power source (AC fail), battery loss or
battery low voltage (battery trouble) with indication provided on the
keypad
•
Internal clock locked to AC power frequency
Operating Environmental Conditions
•
Temperature range: UL= 0°C to +49°C (32°F-120°F),
•
Relative humidity: <93% non condensing
Alarm Transmitter Equipment (ATE) Specification
•
Digital dialer integral to the main control board
•
Supports SIA and Contact ID
•
Complies with TS203 021-1, -2, -3 Telecom equipment requirements
and EN50136-1-1, EN50136-2-1, EN50136-2-3 ATS 2
•
Optional Dual IP/Cellular communicators (3G2080(R)/ TL2803G(R)/
TL280(R)) can be installed in the same enclosure and configured as pri-
mary or back-up, with AES 128-bit encryption
•
Compliant with EN50136-1-1, EN50136-2-1 ATS2 requirements
System Supervision Features
The PowerSeries Neo continuously monitors a number of possible trou-
ble conditions and provides audible and visual indication at the keypad.
Trouble conditions include:
• AC power failure
• Zone trouble
• Fire trouble
• Telephone line trouble
• Communicator trouble
• Low battery condition
• RF jam
• AUX power supply fault
• Failure to communicate
• Module fault (supervisory or tamper)
Additional Features
•
2-way wireless device support
•
Visual verification ( audio)*
•
Proximity tag support
•
PGM scheduling
•
Quick arming
•
User, partition, module, zone and system labels
•
Programmable system loop response
•
Keypad and panel software versions viewable through keypad
•
Doorbell zone type
•
Low battery PGM type
*Feature not evaluated by UL/ULC.