100
Opening Events
[308]-[201] User Openings - Disarmed by user
O/C
(4)A1-UUU
OP-UUUU
[308]-[202] Automatic Arming Canceled
O/C
(4)55-000
CI-0000
[308]-[201] Special Opening - System disarmed using: keyswitch, maintenance code, DLS
software, wireless key
O/C
(4)AA-000
OP-0000
[308]-[211] Late to Open - System not disarmed before late to open time expired
O/C
E(4)53-000
CT-0000
[308]-[202] Automatic (Schedule) Opening
O/C
(4)A3-000
OA-0000
Closing Events
[308]-[201] User Closings - System armed by user
O/C
E(4)A1-UUU
CL-UUUU
[308]-[221] Partial Closing - 1 or more zones bypassed when armed
O/C
(4)56-000
CG-0000
[308]-[201] Special Closing - System armed via: quick arm, keyswitch, function key, mainte-
nance code, DLS software, wireless key
O/C
(4)AA-000
CL-0000
[308]-[211] Late to Close - Auto-arm prealert sounded
O/C
(4)A3-000
CA-0000
[308]-[211] Exit Fault
O/C
(3)74-ZZZ
EA-ZZZZ
System Trouble Events
[308]-[301] Battery trouble/restore - Main panel
MA/R
(3)A2-000
YT-0000/YR-0000
[308]-[301] Battery absent trouble/restore - Main panel
MA/R
(3)11-000
YM-0000/YR-0000
[308]-[301] Battery charging trouble/restore - Main panel
MA/R
(3)AA-000
YP-0000/YQ-0000
[308]-[301] Panel AC trouble/restore - Main panel
MA/R
(3)A1-000
AT-0000/AR-0000
[308]-[302] Bell Circuit trouble/restore
MA/R
(3)21-000
YA-0999/YH-0999
[308]-[302] TLM (telephone line) fail/restore
MA/R
(3) 51-000
LT-0001/LR-0001
[308]-[302] Auxiliary Power trouble/restore
MA/R
(3) 12-000
YP-0000/YQ-0000
[308]-[305] PGM 2, 2-Wire Smoke trouble/restore
MA/R
(3)73-992
FT-0992/FJ-0992
Module Troubles
[308]-[332] Hardwired Module Low Voltage trouble/restore - System
MA/R
(3)AA-000
EM-0000/EN-0000
[308]-[332] Hardwired Module Low Voltage trouble/restore - Keypads
MA/R
(3)AA-001-032
EM-0001-0032
EN-0001-0032
[308]-[332] Hardwired Module Low Voltage trouble/restore - HSM2108
MA/R
(3)AA-101-162
EM-0101-0162
EN-0101-0162
[308]-[332] Hardwired Module Low Voltage trouble/restore - HSM2208
MA/R
(3)AA-201-262
EM-0201-0262
EN-0201-0262
[308]-[332] Hardwired Module Low Voltage trouble/restore - HSM2HOST
MA/R
(3)AA-551
EM-0551
EN-0551
[308]-[332] Hardwired Module Low Voltage trouble/restore - HSM2204
MA/R
(3)AA-601-604
EM-0601-0601
EN-0601-0604
[308]-[332] Hardwired Module Low Voltage trouble/restore - HSM2300
MA/R
(3)AA-621-624
EM-0621-0624
EN-0621-0624
[308]-[332] Hardwired Module Supervisory trouble/restore - System
MA/R
(3)A-000
ET-0000/ER-0000
[308]-[332] Hardwired Module Supervisory trouble/restore - Keypads
MA/R
(3)A-001-032
ET-0001-0032
ER-0001-0032
[308]-[332] Hardwired Module Supervisory trouble/restore - HSM2108
MA/R
(3)A-101-162
ET-0101-0162
ER-0101-0162
[308]-[332] Hardwired Module Supervisory trouble/restore - HSM2208
MA/R
(3)A-201-262
ET-0201-0262
ER-0201-0262
[308]-[332] Hardwired Module Supervisory trouble/restore - HSM2HOST
MA/R
(3)A-551
ET-0551
ER-0551
[308]-[332] Hardwired Module Supervisory trouble/restore - HSM2204
MA/R
(3)A-601-604
ET-0601-0601
ER-0601-0604
[308]-[332] Hardwired Module Supervisory trouble/restore - HSM2300
MA/R
(3)A-621-624
ET-0621-0624
ER-0621-0624
[308]-[332] Hardwired Module Supervisory trouble/restore
MA/R
(3)3A-MMM
ET-MMMM/ER-
MMMM
[308]-[332] HSM2204 Aux Supply 1 trouble/restore
MA/R
(3)12-601
YI-0601/YJ-0601
[308]-[332] HSM2204 Aux Supply 2 trouble/restore
MA/R
(3)12-602
YI-0602/YJ-0602
[308]-[332] HSM2204 Aux Supply 3 trouble/restore
MA/R
(3)12-603
YI-0603/YJ-0603
[308]-[332] HSM2204 Aux Supply 4 trouble/restore
MA/R
(3)12-604
YI-0604/YJ-0604
Section #
Definition
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto
Rep Codes**
firealarmresources.com